Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
10/15/2009
Applicant:
N/A
Description:
TI:RESTAURANT
Architects:
  • LARA, ROBERT G
Contractors:
  • RIO WEST DEVELOPMENT AND CONSTR *C*

Permit Reviews

Permit Number - T09CM02765
Permit Status: C of o
Permit Description: TI:RESTAURANT
Start Date Submittal Complete Date Status  
10/15/2009 COMMERCIAL TI 11/05/2009 COMPLETED Review Details
11/05/2009 RESUBMITTAL 11/10/2009 COMPLETED Review Details
11/10/2009 RESUBMITTAL 11/12/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM02765
Permit Status: C of o
Permit Description: TI:RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
10/15/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T09CM02765
Permit Description: TI:RESTAURANT
Total Completed Inspections - 22
Date Description Inspector Results Comments
11/16/2009 ELECTRIC - INTERMEDIATE RMORENO Approved IVRS - Inspection :*
1) BAR COUNTER AND SOUTHWALL OK
11/16/2009 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
11/16/2009 FRAMING JBURGE Approved IVRS - Inspection :*
11/16/2009 ROOF NAILING JBURGE Approved IVRS - Inspection :*
11/16/2009 RIGHT OF WAY - FINAL PWHIDDON Approved
11/16/2009 ELECTRIC - ABOVE CEILING RMORENO Approved IVRS - Inspection :*
11/17/2009 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
1) OK TO TAPE THROUGHOUT
11/18/2009 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
11/18/2009 PLUMBING - PRE SLAB BBENEDON Approved IVRS - Inspection :*
11/20/2009 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
11/20/2009 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
11/20/2009 NPPO - FINAL JLINVILLE Approved N/A
11/20/2009 LANDSCAPE - FINAL JLINVILLE Approved N/A
12/08/2009 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
12/11/2009 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
1) PROVIDE TRAPS ON INDIRECT DRAINS OVER 5' AND PROVIDE AGS
2) SWEEP AT DW DRAIN
3) ACCESS ABOVE BACKFLOWS FOR SERVICE
4) NON-CARBONATED BEVERAGES REQUIRE BACKFLOW PROTECTION SEPARATE OF CARBONATED
C OF O ISSUES:
1) PROVIDE A FLOOR PLAN OF EXISTING FIXTURE HOSE BIBS AND VACUUM BREAKERS
2) CAULKING AT FIXTURES REPLACED
3) PETITION OF APPEAL REQUIRED FOR WATERLESS URINALS
4) PROPER INDIRECT WASTE PIPING WITH MIN AIR GAPS
5) BACKFLOW CERTS FOR EXISTING ASSEMBLIES
6) RECONNECT EQUIPMENT
7) LIST MAY NOT BE COMPLETE
12/11/2009 PLUMBING - PROGRESS BBENEDON Approved
12/11/2009 ENGINEERING - FINAL DROBERTS Approved
12/11/2009 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
12/11/2009 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
12/15/2009 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
1) ALL TRADES AND FIRE FINALS ARE COMPLETE
12/15/2009 FIRE - FINAL DRamirez Approved Approved 12/15/09.
12/18/2009 HEALTH DEPT - FINAL 724-7908 ERICA LOPEZ Approved

Documents

File Name Document Type  
C OF O_12-18-2009.TIF CERT OF OCC VIEW
001_A1.0.TIF CONSTRPLANS VIEW
002_A2.0.TIF CONSTRPLANS VIEW
003_A3.0.TIF CONSTRPLANS VIEW
004_A4.0.TIF CONSTRPLANS VIEW
005_E-1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW