Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address NEW:
1250 S PANTANO RD
Apply Date:
10/06/2009
Applicant:
N/A
Description:
NEW:CONVENIENCE STORE #1460
Architects:
  • FILUK, DANIEL DIMITRI
Contractors:
  • HAWORTH CORPORATION , THE

Permit Reviews

Permit Number - T09CM02693
Permit Status: C of o
Permit Description: NEW:CONVENIENCE STORE #1460
Start Date Submittal Complete Date Status  
01/26/2010 REVISION - - 1ST 01/26/2010 COMPLETED Review Details
10/06/2009 PLANS OK TO SUBMIT - COMM 10/06/2009 COMPLETED Review Details
10/06/2009 COMMERCIAL NEW 11/06/2009 COMPLETED Review Details
11/06/2009 RESUBMITTAL 01/05/2010 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM02693
Permit Status: C of o
Permit Description: NEW:CONVENIENCE STORE #1460
Total Outstanding Activity Conditions - 1
Date Name
10/06/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T09CM02693
Permit Description: NEW:CONVENIENCE STORE #1460
Total Completed Inspections - 45
Date Description Inspector Results Comments
12/30/2009 EXCAVATION/LAYOUT REBAR & ZON GDABBS Approved IVRS - Inspection :*
STORE BLDG FOOTING REBAR & EXCAVATION OK
SPECIAL INSPECTION BY KEILFELDER
12/30/2009 ELECTRIC - UFER RMORENO Approved IVRS - Inspection :*
01/04/2010 STEM WALL/RETAINING WALL GDABBS Approved IVRS - Inspection :*
1) CMU STEM WALLS AT STORE STRUCTURE (2 COURSES) OK TO GROUT
2) PAID AFTER HOURS INSPECTION AND RECEIVED $150.00 CHECK #02778
01/11/2010 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
01/14/2010 BUILDING PRE-SLAB GDABBS Approved IVRS - Inspection :*
01/14/2010 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
02/04/2010 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
02/08/2010 ROOF NAILING GDABBS Approved IVRS - Inspection :*
1) ROOF DECK PUDDLE WELDS AND BUTTON PUNCH JOISTS AND X-BRACING OK
2) SPECIAL INSPECTION BY KLEINFELDER
02/16/2010 FRAMING GDABBS Approved IVRS - Inspection :*
02/18/2010 PLUMBING - ROOF DRAINS RRICH Approved IVRS - Inspection :*
02/18/2010 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
02/18/2010 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
02/18/2010 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
02/26/2010 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
1) SHEETROCK & PLYWOOD SHEATHING FOR SHELVING; RESTROOMS OK TO TAPE THROUGHOUT
03/26/2010 ELECTRIC - TEMPORARY SERVICE RJIROUDE Approved IVRS - Inspection :*
1) ELECTRICAL CONTRACTOR TO USE LOCK OUT PROCEDURES TO ENSURE CONTROL OF DISTRIBUTION SYSTEM
03/29/2010 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED PER R. JIROUDEK
03/30/2010 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
1) INDIRECT DRAIN AT COFFEE BAR OK
03/30/2010 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
03/31/2010 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) INSULATE LINEAR BOXES WITH MINIMUM R4.2 WILL CHECK ON FINAL
03/31/2010 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
03/31/2010 BUILDING ABOVE CEILING GDABBS Approved IVRS - Inspection :*
04/14/2010 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
1) AIR BALANCE AND DUCT SMOKE DETECTOR TEST OK
2) OK FOR FINAL
04/15/2010 NPPO - FINAL DROBERTS Approved
04/15/2010 LANDSCAPE - FINAL DROBERTS Approved
04/15/2010 ENGINEERING - FINAL DROBERTS Approved THE SITE WAS CHECKED FOR THE ENGINEERING ASPECTS AND HAS BEEN APPROVED AT THIS TIME. AN AS-BUILT OF THE GRADING PLANS HAS BEEN PROVIDED ALONG WITH A CERTIFICATION LETTER FROM THE ENGINEER OF RECORD.
04/15/2010 FIRE SPKLR - FINAL CSCHULTZ Approved
04/15/2010 FIRE - FINAL CSCHULTZ Approved
04/15/2010 REINFORCED MASONRY PRE-GROUT GDABBS Approved IVRS - Inspection :*
04/15/2010 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
04/15/2010 BUILDING - PROGRESS GDABBS Approved IVRS - Inspection :*
04/15/2010 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
04/15/2010 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
04/15/2010 OUTDOOR LIGHTING FINAL RJIROUDE Approved IVRS - Inspection :*
04/15/2010 ELECTRIC - OUTDOOR LIGHTING RJIROUDE Approved IVRS - Inspection :*
04/15/2010 ELECTRIC - TEMP POWER FOR TEST RJIROUDE Approved IVRS - Inspection :*
04/15/2010 ELECTRIC - PROGRESS RJIROUDE Approved IVRS - Inspection :*
04/15/2010 ELECTRIC - CABLE DROP RJIROUDE Approved IVRS - Inspection :*
04/15/2010 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
04/15/2010 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
04/15/2010 ELECTRIC - UNDERGROUND RJIROUDE Approved IVRS - Inspection :*
04/16/2010 BUILDING - FINAL MHENSON Approved IVRS - Inspection :*
1) HAD COMPLIANT SPECIAL INSPECTIONS ON SITE
04/19/2010 SIGN - FINAL JYBARRA Approved
04/20/2010 RIGHT OF WAY - FINAL MCASTRO Approved
04/20/2010 HEALTH DEPT - FINAL 724-7908 NRAMIREZ Approved
04/20/2010 STUCCO MESH MHENSON Approved