Inspection History: PLUMBING - FINAL

Permit Number - T09CM02693

Inspection Description - PLUMBING - FINAL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
04/15/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
04/15/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
04/12/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) COMPLETE INSULATION ON HOT AND HOT RETURN PIPING
2) INSTALL PAN DRAIN FOR WATER HEATER PER DETAIL 516
3) ALL INDIRECT DRAINS TO HAVE CORRECT AIR GAP
4) PROVIDE LABELING FOR NON POTABLE WATER FOR POWER WASH BOX PER SCHEDULE P1.1
5) PROVIDE LABELS FOR GROUNDED BACKFLOW PROTECTION DEVICES
6) COMPLETE ALL INSTALLS OF ALL EQUIPMENT
7) PROVIDE LADDER ACCESS TO ROOF
8) INSTALL ROOF DRAIN TONGUES