Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Address NEW:
3595 E BROADWAY BL
Apply Date:
09/17/2009
Applicant:
N/A
Description:
SHELL:REMODEL
Contractors:
  • BARKER MORRISSEY CONTRACTING INC **C

Permit Reviews

Permit Number - T09CM02528
Permit Status: Final
Permit Description: SHELL:REMODEL
Start Date Submittal Complete Date Status  
09/17/2009 PLANS OK TO SUBMIT - COMM 09/21/2009 COMPLETED Review Details
09/21/2009 3RD PARTY REVIEW-COMMERCIAL TI 10/28/2009 COMPLETED Review Details
10/28/2009 POST 3RD PARTY REVIEW 11/02/2009 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T09CM02528
Permit Status: Final
Permit Description: SHELL:REMODEL
Total Outstanding Activity Conditions - 1
Date Name
09/17/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09CM02528
Permit Description: SHELL:REMODEL
Total Completed Inspections - 27
Date Description Inspector Results Comments
11/13/2009 REINFORCED MASONRY PRE-GROUT JBURGE Approved IVRS - Inspection :*
1) MASONRY WALL AT LOADING DOCK; DETAILS #102, 108 PAGE S5.0 AT 0'-8" WITH CLEANOUTS-OK TO GROUT
11/20/2009 SHEET ROCK NAILING JBURGE Approved RESTROOMS AND ABOVE CEILING ONE SIDED-OK TO TAPE PROGRESS AREAS
11/21/2009 BUILDING PRE-SLAB GDABBS Approved IVRS - Inspection :*
1) PLUMBING TRENCH NORTH TO SOUTH IN FILL OF SLAB VIEWED DOWELING AND BACKFILL-OK TO POUR
2) CHARGE TO BARKER/MORRISSEY AFTER HOURS INSPECTION ACCT. $150.00 AFTER HOURS INSPECTION FEE
11/24/2009 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
11/24/2009 ENGINEERING - FINAL MRUSSO Approved PERMIT NOT TO BE APPROVED UNTIL TO9CM02764 IS COMPLETED AND APPROVED. SUPERINTENDENT CRAIG 260--0498 W/ BARKER MORRISSEY
12/01/2009 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
1) FROM MANHOLE THRU BLDG PER PLAN APPROVED
2) REMINDER CALL IN YOUR DEMO PERMIT
12/01/2009 SITE - SEWER RRICH Approved IVRS - Inspection :*
12/01/2009 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
12/02/2009 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
1) APPROVED PER LEE RAY
12/11/2009 ELECTRIC - INTERMEDIATE RMORENO Approved IVRS - Inspection :*
BOTH BATHROOM,LITING, POWER ALL OK
12/11/2009 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
12/14/2009 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
RESTROOMS 111, 112 OK
BACTERIA REPORT ON SITE
12/16/2009 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
1) UNITS ON ROOF ARE NOW IN PLACE-OK TO PROCEED
12/16/2009 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
1) OK ROUGH AND TERMINATIONS FOR A/C UNITS
12/16/2009 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
12/21/2009 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
1) CONDENSATE DRAINS NOT SIZED CORRECTLY, SEE CITY OF TUCSON AMMENDMENTS
12/21/2009 FRAMING GDABBS Approved IVRS - Inspection :*
1) ROOF LINE STUCCO POP OUT FRAMING COMPLETE-OK TO COVER
01/12/2010 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
1) OK FOR FINAL
01/12/2010 FIRE SPKLR - FINAL LTHOMAS Approved Approved
01/12/2010 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
01/14/2010 ROOF NAILING GDABBS Approved IVRS - Inspection :*
01/19/2010 RIGHT OF WAY - FINAL MOTERO Approved
01/19/2010 SIGN - FINAL JYBARRA Approved
01/26/2010 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED FOR "#2 METER" PER D. SANTACRUZ
02/02/2010 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
02/05/2010 FIRE - FINAL LTHOMAS Approved Approved
02/26/2010 FIRE SPKLR - UG PIPING FLUSH FIRE Approved