Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T09CM02528
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/02/2009 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) APPROVED PER LEE RAY |
|
11/21/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) PER APPEAL FROM BLDG OFFICIAL, PER LEE RAY HANLY, PIPE COVER WITH CLEANOUT CONCRETE INCASED IN BOTTOM OF (FOUND EXISTING MANHOLE IN BLDG OVER 8" CLAY PIPING) CLEANOUT BROUGHT TO FINISH FLOOR ELEVATION, REMAINDER OF MANHOLE FILLED WITH PEA GRAVEL TO TOP OF MANHOLE 2) PAID $150.00 FROM BARKER/MORRISEY APA ACCOUNT |
|
11/20/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) WATER TEST ON 4" BLDG DRAIN FROM R. MYERS THRU TO EXTERIOR 2 WAY CLEANOUT PARTIAL 2) REPAIR LEAK AT 2ND INLINE CLEANOUT FROM RESTROOM DOWN STREAM ------------------------------------------------------------------------------------------------- 1) PAID $150.00 FROM BARKER/MORRISEY APA ACCOUNT 2) WATER TEST FROM RESTROOM THRU 2 WAY CLEANOUT AT EXTERIOR OK PER INITIAL MP1.0 DATED 10/27/09 (STANTEC) PENDING NOTES FROM 11/13/09 INSPECTION HISTORY |
|
11/19/2009 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL PER APPROVED PLAN 2) PROVIDE CITY APPROVED PLAN FOR CHANGES NOTE: 1) MAN HOLES HAVE BEEN INDENTIFIED OVER CLAY PIPING ON INTERIOR OF BLDG |
|
11/13/2009 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) MATERIAL SPEC CALLS FOR PVC INSTALLED IS ABS/PROVIDE LETTER APPROVING ABS, OR INSTALL PVC 2) PIPING AS INITIALED ON MP1.0 OK TO COVER SUBJECT TO APPROVAL OF MATERIAL TYPE |