Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T09CM02280
Permit Details
Apply Date:
08/26/2009
Applicant:
N/A
Description:
ADDITION: PORCH
Permit Reviews
Permit Number - T09CM02280
Permit Status: Final
Permit Description: ADDITION: PORCH
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/26/2009 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 08/26/2009 | COMPLETED |
10/01/2009 | REVISION - - 1ST | 10/01/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM02280
Permit Status: Final
Permit Description: ADDITION: PORCH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/26/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM02280
Permit Description: ADDITION: PORCH
Total Completed Inspections - 11
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2009 | BUILDING PRE-SLAB | RFREIDIN | Approved | IVRS - Inspection :* |
08/28/2009 | EXCAVATION/LAYOUT REBAR & ZON | RFREIDIN | Approved | IVRS - Inspection :* |
09/17/2009 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
09/24/2009 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection :* 1) NOTE: J-BOX TO BE LEFT ACCESSIBLE. BRING OUT FLUSH WITH DRYWALL CAN BE COVERED WITH A BLANK COVER 2) LOOKING AT YOUR PLANS, ONE PAGE SHOWS A ROOF STRUCTURE. BEFORE COVERING CEILING WITH DRYWALL. COLUMNS 6" X6" POST HAVE NO BEARING SURFACE OR ANCHORAGE BEFORE COVERING CALL IN AN INSPECTION. CAN'T FIND ANY HOLDOWN CONNECTION ON PLAN |
10/13/2009 | FRAMING | RFREIDIN | Approved | IVRS - Inspection :* 1) NOTE: OK FOR 1ST FLOOR |
10/13/2009 | STUCCO MESH | RFREIDIN | Approved | IVRS - Inspection :* |
10/22/2009 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* 1) HARD LID AT UNDERSIDE OF PORCH |
11/25/2009 | BUILDING - PROGRESS | RFREIDIN | Approved | IVRS - Inspection :* 1) ROOF DECK AND UPPER DECK FRAMING |
03/30/2010 | ELECTRIC - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
03/30/2010 | BUILDING - FINAL | RFREIDIN | Approved | IVRS - Inspection :* |
03/31/2010 | PERMIT FINALED | JWEATHER | Approved |