Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
1325 S SAN JACINTO DR
Apply Date:
08/05/2009
Applicant:
N/A
Description:
A/C UNIT RES

Outstanding Activity Conditions

Permit Number - T09CM02089
Permit Status: Expired
Permit Description: A/C UNIT RES
Total Outstanding Activity Conditions - 1
Date Name
08/05/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09CM02089
Permite Description: A/C UNIT RES
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
08/07/2009 PLUMBING - GAS PRESS TEST FNL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/07/2009 MECHANICAL - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PROPER SUPPORT FOR GAS PIPING
2) PROVIDE APPROVED LOAD CALC FROM CITY OF TUCSON
3) UNIT IS NOT LEVEL. NEED TO CORRECT
4) ALL ROOF TOP DUCT TO BE R-8 (2") INSULATION
5) UNIT NOT PROPERLY WIRED, WIRES NOT CORRECTLY IDENTIFIED
6) CONDENSATE NOT RUN, MUST BE TERMINATED AT AN APPROVED LOCATION
7) ALL DUCT JOINTS MUST BE SEALED
8) ELECTRICAL CONDUIT TO BE BLOCKED UP OFF OF ROOF
9) PROVIDE WATER TIGHT 110 V SERVICE RECT. GFCI ON ROOF WITHIN 25' OF UNIT

Completed Inspections

Permit Status: Expired
Permit Number: T09CM02089
Permit Description: A/C UNIT RES
Total Completed Inspections - 1
Date Description Inspector Results Comments
08/06/2009 MECHANICAL - INTERMEDIATE RCAMACHO Approved IVRS - Inspection :*