Permit: T09CM02050
Permit Details
Apply Date:
07/31/2009
Applicant:
N/A
Description:
SECONDARY DWELLING
Permit Reviews
Permit Number - T09CM02050
Permit Status: Expired
Permit Description: SECONDARY DWELLING
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/31/2009 | PLANS OK TO SUBMIT - RES | 12/21/2009 | COMPLETED |
12/23/2009 | RESIDENTIAL BLDG/WWM | 12/23/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM02050
Permit Status: Expired
Permit Description: SECONDARY DWELLING
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/31/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T09CM02050
Permite Description: SECONDARY DWELLING
Total Outstanding Inspections - 15
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EXT METAL CLIPS/EXT SHEATHING | N/A | Not Inspected | ||
SHEET ROCK NAILING | N/A | Not Inspected | ||
BUILDING - FINAL | N/A | Not Inspected | ||
ELECTRIC - CABLE DROP | N/A | Not Inspected | ||
ELECTRIC - TEMPORARY SERVICE | N/A | Not Inspected | ||
ELECTRIC - FINAL | N/A | Not Inspected | ||
PLUMBING - YARD WTR LINE/TEST | N/A | Not Inspected | ||
PLUMBING - SEWER HCS CONNECT | N/A | Not Inspected | ||
PLUMBING - FINAL | N/A | Not Inspected | ||
MECHANICAL - FINAL | N/A | Not Inspected | ||
02/11/2010 | ROOF NAILING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEFT MESSAGE 9:20 AM 2) EXPOSE FOOTERS POURED WITHOUT INSPECTION TO VERIFY DEPTH PER PLAN 2) PROVIDE LETTERHEAD FROM LICENSED PLUMBER WHO DID UNDERGROUND WORK TO CODE OR EXPOSE FOR INSPECTION 3) ROOF HAS BEEN DRIED IN PRIOR TO INSPECTION-REMOVE 100 SQUARE FOR INSPECTION 4) RECALL 1025 & 1030 NEXT INSPECTION |
10/19/2011 | FRAMING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONSULT WITH QUALIFIED ELECTRICIAN 2) ALL ROMEX TERMINATED INTO APPROVED BOX. SERVICE ROMEX 8" FROM BOXES THROUGHOUT 3) INSTALL RANGE CIRCUIT 4) 2-20 AMP GFCI SMALL APPLIANCE CIRCUITS KITCHEN 12-2 WIRE 5) ISOLATE REFRIDGERATOR CIRCUIT 20 AMP 6) MAKE UP ALL SWITCHES PIG TAIL GROUNDS 7) MISSING CIRCUIT 2 SMOKE ALARM CIRCUIT 14-3 WIRING 8) MISSING CIRCUITS 12, 13, 14 & 15 BASE BOARD HEATERS 12-2 WIRING 9) PROVIDE SWITCHED LIGHT FIXTURES EXIT DOORS 10) MISSING BATH 20 AMP 12-2 OUTLET. TERMINATE EXHAUST FAN WIRING INTO BOX 11) TERMINATE HOMERUNS INTO PANEL 12) BEDROOM WINDOWS SILL HEIGHT ABOVE 44" MINIMUM OPENING SIZE 20" X 24"-20" WIDTH 13) FIREBLOCK DROPPED CEILINGS 14) STOPPED INSPECTION |
10/19/2011 | U VALUE FOR WINDOW | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
10/19/2011 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
12/03/2010 | PLUMBING - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* 1) PENDING NOTE 2 FROM PREVIOUS 2) ALL TESTS OK |