Permit Details

Status:
Expired
Type:
SINGLE FAMILY NEW
Apply Date:
07/31/2009
Applicant:
N/A
Description:
SECONDARY DWELLING

Permit Reviews

Permit Number - T09CM02050
Permit Status: Expired
Permit Description: SECONDARY DWELLING
Start Date Submittal Complete Date Status  
07/31/2009 PLANS OK TO SUBMIT - RES 12/21/2009 COMPLETED Review Details
12/23/2009 RESIDENTIAL BLDG/WWM 12/23/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM02050
Permit Status: Expired
Permit Description: SECONDARY DWELLING
Total Outstanding Activity Conditions - 1
Date Name
07/31/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09CM02050
Permite Description: SECONDARY DWELLING
Total Outstanding Inspections - 15
Last Inspection Date Description Inspector Results Comments
EXT METAL CLIPS/EXT SHEATHING N/A Not Inspected
SHEET ROCK NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - CABLE DROP N/A Not Inspected
ELECTRIC - TEMPORARY SERVICE N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
PLUMBING - YARD WTR LINE/TEST N/A Not Inspected
PLUMBING - SEWER HCS CONNECT N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
MECHANICAL - FINAL N/A Not Inspected
02/11/2010 ROOF NAILING N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LEFT MESSAGE 9:20 AM
2) EXPOSE FOOTERS POURED WITHOUT INSPECTION TO VERIFY DEPTH PER PLAN
2) PROVIDE LETTERHEAD FROM LICENSED PLUMBER WHO DID UNDERGROUND WORK TO CODE OR EXPOSE FOR INSPECTION
3) ROOF HAS BEEN DRIED IN PRIOR TO INSPECTION-REMOVE 100 SQUARE FOR INSPECTION
4) RECALL 1025 & 1030 NEXT INSPECTION
10/19/2011 FRAMING N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CONSULT WITH QUALIFIED ELECTRICIAN
2) ALL ROMEX TERMINATED INTO APPROVED BOX. SERVICE ROMEX 8" FROM BOXES THROUGHOUT
3) INSTALL RANGE CIRCUIT
4) 2-20 AMP GFCI SMALL APPLIANCE CIRCUITS KITCHEN 12-2 WIRE
5) ISOLATE REFRIDGERATOR CIRCUIT 20 AMP
6) MAKE UP ALL SWITCHES PIG TAIL GROUNDS
7) MISSING CIRCUIT 2 SMOKE ALARM CIRCUIT 14-3 WIRING
8) MISSING CIRCUITS 12, 13, 14 & 15 BASE BOARD HEATERS 12-2 WIRING
9) PROVIDE SWITCHED LIGHT FIXTURES EXIT DOORS
10) MISSING BATH 20 AMP 12-2 OUTLET. TERMINATE EXHAUST FAN WIRING INTO BOX
11) TERMINATE HOMERUNS INTO PANEL
12) BEDROOM WINDOWS SILL HEIGHT ABOVE 44" MINIMUM OPENING SIZE 20" X 24"-20" WIDTH
13) FIREBLOCK DROPPED CEILINGS
14) STOPPED INSPECTION
10/19/2011 U VALUE FOR WINDOW N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/19/2011 ELECTRIC - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/03/2010 PLUMBING - INTERMEDIATE N/A Partial Approval IVRS - Inspection :*
1) PENDING NOTE 2 FROM PREVIOUS
2) ALL TESTS OK