Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY COMPLIANCE
Address:
1504 E EL ATAJO
Address NEW:
1504 E EL ATAJO
Apply Date:
07/29/2009
Applicant:
N/A
Description:
CODE COMPLIANCE:ENCLOSE:CARPORT TO GARAGE:ADDITION:MASTER BEDROOM

Permit Reviews

Permit Number - T09CM02022
Permit Status: Expired
Permit Description: CODE COMPLIANCE:ENCLOSE:CARPORT TO GARAGE:ADDITION:MASTER BEDROOM
Start Date Submittal Complete Date Status  
07/29/2009 RESIDENTIAL BLDG/ZONING-WALKTHRU 07/30/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM02022
Permit Status: Expired
Permit Description: CODE COMPLIANCE:ENCLOSE:CARPORT TO GARAGE:ADDITION:MASTER BEDROOM
Total Outstanding Activity Conditions - 1
Date Name
07/29/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09CM02022
Permite Description: CODE COMPLIANCE:ENCLOSE:CARPORT TO GARAGE:ADDITION:MASTER BEDROOM
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
07/31/2009 BUILDING - PROGRESS N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REAR BEDROOM ADDITION IS NOT AS PER DRAWING SUBMITTED-2 X 6'S SPANNING 14'-7" AT 24" ON CENTER-UNABLE TO INSTALL R-30 INSULATION IN THIS SPACE
2) WEEP SCREED AT STUCCO SHALL BE 4" MINIMUM FROM EARTH RAISE WOOD FRAME 6" MINIMUM FROM EARTH. APPEARS WOOD FRAME IS FLUSH WITH GROUND
3) EXPOSE BEAM BETWEEN EXISTING BEDROOM AND ADDITION TO VERIFY SIZE AND CONNECTION AT EACH BEARING POINT
4) CONNECTION AT PORCH 2 X 6 TO FASCIA NOT ALLOWED, SUBMIT AS BUILT TO DSD PLANS EXAMINER FOR APPROVAL
5) HAVE LICENSED ELECTRICIAN VERIFY IN WRITING THAT ELECTRIC IS TO CODE
6) CARPORT ENCLOSURE TO GARAGE SHALL HAVE MAN DOOR BE SELF CLOSING
07/31/2009 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*