Permit: T09CM01544
Permit Details
Apply Date:
06/17/2009
Applicant:
N/A
Description:
TI: RELIGIOUS CENTER
Architects:
- EWING, CARL C
Permit Reviews
Permit Number - T09CM01544
Permit Status: C of o
Permit Description: TI: RELIGIOUS CENTER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/19/2010 | REVISION - - 1ST | 01/19/2010 | COMPLETED |
| 06/17/2009 | COMMERCIAL TI | 07/02/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM01544
Permit Status: C of o
Permit Description: TI: RELIGIOUS CENTER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/17/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T09CM01544
Permit Description: TI: RELIGIOUS CENTER
Total Completed Inspections - 23
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2009 | FRAMING | MHENSON | Approved | IVRS - Inspection :* 1) NEED PLAN REVISED SHOWING NEW WINDOWS AND IN FILL NOT DONE 2) SLAB AND FOOTING POURED WITHOUT INSPECTION IS NOT ACCESSIBLE FROM EXTERIOR AS PLAN SHOWS 3) NO DRYWALL TO BE HUNG WITHOUT TRADE INSPECTIONS |
| 09/15/2009 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* 1) BOND WATER AND GAS PIPING 2) USE PROPER FITTINGS FOR LOAD CONDUIT TERM INTO ENCLOSURE 3) USE INSULATED BUSHING TO PROTECT CABLE FROM ABRAISON AT END OF CONDUIT ABOVE PANEL 4) SUPPORT ROMEX INSIDE ADDITION PER CODE-USE APPROVED FAN BOX, BUSHINGS ON ENDS OF WIREMOLD TO PROTECT ROMEX, NAIL PLATES WHERE NECESSARY 5) FEED TO ADDITION NOT RUN YET |
| 09/15/2009 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | IVRS - Inspection :* |
| 09/15/2009 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* |
| 09/16/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED PER D. SANTACRUZ |
| 09/23/2009 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* 1) OK WALLS/CEILING INSIDE ADDITION 2) INSTALL CORRECT CONNECTORS AT SERVICE |
| 09/23/2009 | ELECTRIC - PROGRESS | DSANTACR | Approved | IVRS - Inspection :* |
| 09/23/2009 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
| 10/28/2009 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR FINAL |
| 10/28/2009 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 11/12/2009 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* |
| 11/12/2009 | PLUMBING - GAS PRESS TEST FNL | RRICH | Approved | IVRS - Inspection :* |
| 11/12/2009 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |
| 12/23/2009 | BUILDING - FINAL | MHENSON | Approved | IVRS - Inspection :* 1) WAITING ON REVISED PLAN FOR FRAMING FINAL |
| 12/23/2009 | SHEET ROCK NAILING | MHENSON | Approved | IVRS - Inspection :* |
| 01/20/2010 | FIRE - FINAL | MOTERO | Approved | |
| 01/20/2010 | FIRE - FINAL | DSIWARSKI | Approved | No Access |
| 01/20/2010 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 01/20/2010 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
| 01/21/2010 | ELECTRIC - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 01/21/2010 | SIGN - FINAL | JYBARRA | Approved | NO SIGN ON SITE |
| 01/22/2010 | ENGINEERING - FINAL | MRUSSO | Approved | |
| 01/30/2010 | RIGHT OF WAY - FINAL | MCASTRO | Approved |