Permit: T09CM00944
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
2140 E EDISON ST #02
Address NEW:
2140 E EDISON ST #02
Apply Date:
04/22/2009
Applicant:
N/A
Description:
RENOVATE & EXPAND:GUEST HOUSE
Permit Reviews
Permit Number - T09CM00944
Permit Status: Final
Permit Description: RENOVATE & EXPAND:GUEST HOUSE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/22/2009 | PLANS OK TO SUBMIT - RES | 04/23/2009 | COMPLETED |
| 04/23/2009 | RESIDENTIAL BLDG/WWM | 05/22/2009 | COMPLETED |
| 05/22/2009 | RESUBMITTAL | 06/04/2009 | COMPLETED |
| 06/04/2009 | RESUBMITTAL | 07/14/2009 | COMPLETED |
| 09/29/2009 | REVISION - - 1ST | 09/29/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM00944
Permit Status: Final
Permit Description: RENOVATE & EXPAND:GUEST HOUSE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/22/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM00944
Permit Description: RENOVATE & EXPAND:GUEST HOUSE
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/01/2009 | ELECTRIC - TEMPORARY SERVICE | EDURAZO | Approved | |
| 10/01/2009 | ELECTRIC - CABLE DROP | EDURAZO | Approved | IVRS - Inspection :* |
| 10/02/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER E. DURAZO |
| 10/15/2009 | PLUMBING - ROUGH, SOIL | EDURAZO | Approved | IVRS - Inspection :* |
| 10/23/2009 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection :* 1) WRAP PLUMBING EMBEDDED IN CONCRETE WITH FOAM PRIOR TO POUR |
| 10/23/2009 | ELECTRIC - UNDERGROUND | EDURAZO | Approved | IVRS - Inspection :* |
| 10/23/2009 | ELECTRIC - UFER | EDURAZO | Approved | IVRS - Inspection :* |
| 10/23/2009 | BUILDING PRE-SLAB | EDURAZO | Approved | IVRS - Inspection :* |
| 11/25/2009 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | IVRS - Inspection :* 1) OK TO BACKFILL |
| 11/25/2009 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 11/25/2009 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 11/25/2009 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 11/25/2009 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 11/25/2009 | ROOF NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 11/25/2009 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection :* |
| 01/20/2010 | SHEET ROCK NAILING | EDURAZO | Approved | IVRS - Inspection :* |
| 01/20/2010 | STUCCO MESH | EDURAZO | Approved | IVRS - Inspection :* |
| 05/24/2010 | PLUMBING - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/24/2010 | OUTDOOR LIGHTING FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/24/2010 | U VALUE FOR WINDOW | EDURAZO | Approved | IVRS - Inspection :* |
| 05/26/2010 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/26/2010 | ELECTRIC - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/26/2010 | BUILDING - FINAL | EDURAZO | Approved | IVRS - Inspection :* |
| 05/26/2010 | PLUMBING - SEWER HCS CONNECT | EDURAZO | Approved | IVRS - Inspection :* |
| 05/27/2010 | PERMIT FINALED | JWEATHER | Approved |