Start Date Submittal Complete Date Status  
01/04/2011 REVISION - - 2ND 01/04/2011 ACTIVE Review Details
04/20/2009 PLANS OK TO SUBMIT - COMM 04/22/2009 COMPLETED Review Details
04/22/2009 3RD PARTY REVIEW-COMMERCIAL 06/04/2009 COMPLETED Review Details
06/04/2009 POST 3RD PARTY REVIEW 06/25/2009 COMPLETED Review Details
12/16/2009 REVISION - - 1ST 12/22/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM00917
Permit Status: C of o
Permit Description: PARKING GARAGE
Total Outstanding Activity Conditions - 1
Date Name
04/20/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T09CM00917
Permit Description: PARKING GARAGE
Total Completed Inspections - 26
Date Description Inspector Results Comments
12/03/2009 ELECTRIC - UNDERGROUND DSANTACR Approved IVRS - Inspection :*
OK GROUND LEVEL BLDG C CONV OUTLETS U.G.
12/04/2009 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
1) NEED CLARIFICATION OF RFI-48" OR 64" ON CENTER FOR DOWELING
12/23/2009 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
1) OK TO POUR DECK
08/23/2010 FRAMING JBURGE Approved IVRS - Inspection :*
1) MECHANICAL ROOM COMPLETE
12/10/2010 REINFORCED MASONRY PRE-GROUT AQUIROZ Approved IVRS - Inspection :*
1) TOP OUT TRASH ENCLOSURE
12/15/2010 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
12/15/2010 PLUMBING - PRE SLAB RMYERS Approved IVRS - Inspection :*
12/15/2010 OUTDOOR LIGHTING FINAL DSANTACR Approved IVRS - Inspection :*
12/15/2010 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved IVRS - Inspection :*
12/15/2010 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
12/15/2010 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection :*
12/15/2010 ENGINEERING - FINAL MRUSSO Approved 1) PRIOR TO C OF O FOR ENGINEERING APPROVAL, GRADING PERMIT#T09BU00925 MUST BE FINALED AND APPROVED.
2) PROVIDE AN APPROVED SITE/GRADING PLAN FOR INSPECTION.
3) ENSURE COMPLIANCE WITH YOUR STORM WATER PERMIT AND STORM WATER PLAN UNTIL THE SITE IS COMPLETED. SITE IS CURRENTLY IN NON-COMPLIANCE.
4) PRIOR TO FINAL GRADDING APPROVAL (T09BU00925) PROVIDE A CERTIFICATION LETTER FROM YOUR ENG OF RECORD STATING THAT THE SITE WAS CONSTRUCTED PER THE APPROVED GRADING PLAN.
5) PROVIDE AN AS-BUILT DRAWING.
6) COMPLETE ALL SITE/GRADING WORK PRIOR TO FINAL APPROVAL.
12/23/2010 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
1) 2" PIPING INTO DRYWALL WITH DRYWALL OK
12/23/2010 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
12/23/2010 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
12/23/2010 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
12/27/2010 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
1) NEED PLUMBING FINAL
12/29/2010 PLUMBING - ROOF DRAINS RMYERS Approved IVRS - Inspection :*
1) APPROVAL OF RAINWATER LEADERS SUBJECT TO APPROVAL OF REDUCTION FROM 10" TO 8" AT EXTERIOR OF BLDG. MUST BE STAMPED BY BOB SHERRY
2) OK TO COVER
12/29/2010 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
01/03/2011 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
01/03/2011 FIRE - FINAL DSIWARSKI Approved
01/03/2011 SIGN - FINAL JYBARRA Approved
01/04/2011 RIGHT OF WAY - FINAL M.Otero Approved
01/04/2011 NPPO - FINAL MRUSSO Approved
01/04/2011 LANDSCAPE - FINAL MRUSSO Approved
01/06/2011 SITE - SEWER LHANLY Approved

Documents

File Name Document Type  
C OF O_01-06-2011.TIF CERT OF OCC VIEW
001_1.00.TIF CONSTRPLANS VIEW
002_1.01.TIF CONSTRPLANS VIEW
003_2.01.TIF CONSTRPLANS VIEW
004_3.01.TIF CONSTRPLANS VIEW
005_3.02.TIF CONSTRPLANS VIEW
006_3.03.TIF CONSTRPLANS VIEW
007_4.01.TIF CONSTRPLANS VIEW
008_4.02.TIF CONSTRPLANS VIEW
009_4.03.TIF CONSTRPLANS VIEW
010_5.01.TIF CONSTRPLANS VIEW
011_5.02.TIF CONSTRPLANS VIEW
012_5.03.TIF CONSTRPLANS VIEW
013_6.01.TIF CONSTRPLANS VIEW
014_6.02.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW