Permit: T09CM00809
Permit Details
Status:
Final
Type:
SINGLE FAMILY COMPLIANCE
Address:
2514 N SYCAMORE BL
Address NEW:
2514 N SYCAMORE BL
Apply Date:
04/10/2009
Applicant:
N/A
Description:
ADDITION:BEDROOM, STORAGE & CARPORT T08DV11585 BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Permit Reviews
Permit Number - T09CM00809
Permit Status: Final
Permit Description: ADDITION:BEDROOM, STORAGE & CARPORT T08DV11585
BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/10/2009 | RESIDENTIAL BLDG/ZONING/ENGINE/NPPO | 04/16/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T09CM00809
Permit Status: Final
Permit Description: ADDITION:BEDROOM, STORAGE & CARPORT T08DV11585
BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/10/2009 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T09CM00809
Permit Description: ADDITION:BEDROOM, STORAGE & CARPORT T08DV11585
BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/14/2009 | BUILDING - PROGRESS | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE ALL SIDING EXT. WALLS PROPERLY/SIDING MAY NOT REST ON GROUND 2) EXPOSE ALL BOTTOM PLATES 3) CARPORT/STORAGE LAUNDRY 4) 2 X 4 RAFTERS OVER SPANNED 5) PROVIDE PROPER HANGERS THRU-OUT. PROVIDE BEAM TO POST HARDWARE 6) LEDGER TO MASONRY BOLTS OVERSPANNED 7) EXPOSE POST FOOTERS TO VERIFY DEPTH 8) FRAMING TO STORAGE LAUNDRY SUB-STANDARD 9) HAVE LICENSED ELECTRICIAN SUBMIT LETTER HEAD. ALL ELECTRICAL WORK TO CODE TO INCLUDE 220 TO DRYER AND ALL ROMEX ADDED TO ROOMS DEN/BEDROOM: 1) HAZARDOUS ELECTRICAL WIRING EXPOSED THRU-OUT NOTE 7 FROM CARPORT 2) WATER HEATER LACKS REQUIRED COMBUSTION RELIEF TO EXTERIOR. EXTEND TPR LINE TO EXTERIOR OR PAN WITH APPEAL 3) ROOM MISSING OUTLETS PER CODE 4) MISSING SWITCHED FIXTURE TO EXIT DOOR 5) GFCI PROTECT BATH OUTLETS 6) SMOKE ALARMS ALL BEDROOMS AND HALLWAYS 7) REAR BATH DOES NOT APPEAR TO BE EXISTING |
| 06/02/2011 | BUILDING - FINAL | DWALKER | Approved | IVRS - Inspection :* |
| 10/24/2011 | PERMIT FINALED | JWEATHER | Approved |