Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY COMPLIANCE
Address NEW:
2514 N SYCAMORE BL
Apply Date:
04/10/2009
Applicant:
N/A
Description:
ADDITION:BEDROOM, STORAGE & CARPORT T08DV11585 BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.

Permit Reviews

Permit Number - T09CM00809
Permit Status: Final
Permit Description: ADDITION:BEDROOM, STORAGE & CARPORT T08DV11585 BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Start Date Submittal Complete Date Status  
04/10/2009 RESIDENTIAL BLDG/ZONING/ENGINE/NPPO 04/16/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09CM00809
Permit Status: Final
Permit Description: ADDITION:BEDROOM, STORAGE & CARPORT T08DV11585 BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Total Outstanding Activity Conditions - 1
Date Name
04/10/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T09CM00809
Permit Description: ADDITION:BEDROOM, STORAGE & CARPORT T08DV11585 BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Total Completed Inspections - 3
Date Description Inspector Results Comments
10/14/2009 BUILDING - PROGRESS RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE ALL SIDING EXT. WALLS PROPERLY/SIDING MAY NOT REST ON GROUND
2) EXPOSE ALL BOTTOM PLATES
3) CARPORT/STORAGE LAUNDRY
4) 2 X 4 RAFTERS OVER SPANNED
5) PROVIDE PROPER HANGERS THRU-OUT. PROVIDE BEAM TO POST HARDWARE
6) LEDGER TO MASONRY BOLTS OVERSPANNED
7) EXPOSE POST FOOTERS TO VERIFY DEPTH
8) FRAMING TO STORAGE LAUNDRY SUB-STANDARD
9) HAVE LICENSED ELECTRICIAN SUBMIT LETTER HEAD. ALL ELECTRICAL WORK TO CODE TO INCLUDE 220 TO DRYER AND ALL ROMEX ADDED TO ROOMS
DEN/BEDROOM:
1) HAZARDOUS ELECTRICAL WIRING EXPOSED THRU-OUT NOTE 7 FROM CARPORT
2) WATER HEATER LACKS REQUIRED COMBUSTION RELIEF TO EXTERIOR. EXTEND TPR LINE TO EXTERIOR OR PAN WITH APPEAL
3) ROOM MISSING OUTLETS PER CODE
4) MISSING SWITCHED FIXTURE TO EXIT DOOR
5) GFCI PROTECT BATH OUTLETS
6) SMOKE ALARMS ALL BEDROOMS AND HALLWAYS
7) REAR BATH DOES NOT APPEAR TO BE EXISTING
06/02/2011 BUILDING - FINAL DWALKER Approved IVRS - Inspection :*
10/24/2011 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
001_C1.TIF CONSTRPLANS VIEW
002_A1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW