Permit: T09CM00809

Parcel: 110072010


Addresses:

2514 N SYCAMORE BL

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
06/02/2011 BUILDING - PROGRESS Approved IVRS - Inspection :*
04/09/2010 BUILDING - PROGRESS Cancelled CANCELLED PER HOMEOWNER SUSAN #822-4297
04/09/2010 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER OFFICE
10/14/2009 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE ALL SIDING EXT. WALLS PROPERLY/SIDING MAY NOT REST ON GROUND
2) EXPOSE ALL BOTTOM PLATES
3) CARPORT/STORAGE LAUNDRY
4) 2 X 4 RAFTERS OVER SPANNED
5) PROVIDE PROPER HANGERS THRU-OUT. PROVIDE BEAM TO POST HARDWARE
6) LEDGER TO MASONRY BOLTS OVERSPANNED
7) EXPOSE POST FOOTERS TO VERIFY DEPTH
8) FRAMING TO STORAGE LAUNDRY SUB-STANDARD
9) HAVE LICENSED ELECTRICIAN SUBMIT LETTER HEAD. ALL ELECTRICAL WORK TO CODE TO INCLUDE 220 TO DRYER AND ALL ROMEX ADDED TO ROOMS
DEN/BEDROOM:
1) HAZARDOUS ELECTRICAL WIRING EXPOSED THRU-OUT NOTE 7 FROM CARPORT
2) WATER HEATER LACKS REQUIRED COMBUSTION RELIEF TO EXTERIOR. EXTEND TPR LINE TO EXTERIOR OR PAN WITH APPEAL
3) ROOM MISSING OUTLETS PER CODE
4) MISSING SWITCHED FIXTURE TO EXIT DOOR
5) GFCI PROTECT BATH OUTLETS
6) SMOKE ALARMS ALL BEDROOMS AND HALLWAYS
7) REAR BATH DOES NOT APPEAR TO BE EXISTING