Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY COMPLIANCE
Address:
2409 E MABEL ST
Address NEW:
2409 E MABEL ST
Apply Date:
04/16/2009
Applicant:
RANDY TUDISCO
Description:
ADDITION: WOOD PATIO DECK; T08DV07747 FRONT AND REAR PATIO BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.

Permit Reviews

Permit Number - T09BU00559
Permit Status: Expired
Permit Description: ADDITION: WOOD PATIO DECK; T08DV07747 FRONT AND REAR PATIO BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Start Date Submittal Complete Date Status  
04/16/2009 RESIDENTIAL BLDG/ZONING-WALKTHRU 04/16/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T09BU00559
Permit Status: Expired
Permit Description: ADDITION: WOOD PATIO DECK; T08DV07747 FRONT AND REAR PATIO BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Total Outstanding Activity Conditions - 1
Date Name
04/16/2009 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T09BU00559
Permite Description: ADDITION: WOOD PATIO DECK; T08DV07747 FRONT AND REAR PATIO BASELINE DRAWINGS FOR CODE COMPLIANCE INSPECTIONS ONLY.
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
05/26/2009 BUILDING - PROGRESS N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) THERE IS NO APPARENT ROOF LEDGER ATTACHMENT TO HOUSE
2) PORCH AND DECK AREAS MORE THAN 30" ABOVE GRADE REQUIRE SAFETY RAILINGS AT LEAST 36" HIGH WITH NO OPENING GREATER THAN 4"
3) POST TO BEAM ATTACHMENTS ARE INSUFFICIENT
4) THERE IS NO APPARENT POST TO ROOF LEDGER ATTACHMENT
5) 2 X 6 RAFTERS ON 24" ON CENTER HAVE BEEN NOTCHED DOWN TO 4", WHICH IS INSUFFICIENT FOR A TILE ROOF LOAD
6) 4 X6 MID-SPAN BEAM OF 12' NEEDS AN ADDITIONAL POST
7) SUBMIT CORRECTIONS TO PLAN REVIEW
05/26/2009 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Documents

File Name Document Type  
None DOCUMENTS VIEW
001_1.1.TIF CONSTRPLANS VIEW