Inspection History Details
Inspection Status: Denied
Inspection History: BUILDING - PROGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/26/2009 | BUILDING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) THERE IS NO APPARENT ROOF LEDGER ATTACHMENT TO HOUSE 2) PORCH AND DECK AREAS MORE THAN 30" ABOVE GRADE REQUIRE SAFETY RAILINGS AT LEAST 36" HIGH WITH NO OPENING GREATER THAN 4" 3) POST TO BEAM ATTACHMENTS ARE INSUFFICIENT 4) THERE IS NO APPARENT POST TO ROOF LEDGER ATTACHMENT 5) 2 X 6 RAFTERS ON 24" ON CENTER HAVE BEEN NOTCHED DOWN TO 4", WHICH IS INSUFFICIENT FOR A TILE ROOF LOAD 6) 4 X6 MID-SPAN BEAM OF 12' NEEDS AN ADDITIONAL POST 7) SUBMIT CORRECTIONS TO PLAN REVIEW |
|
| 05/20/2009 | BUILDING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) DOG LOOSE IN YARD 2) NO ACCESS 3) PLEASE RECALL |