Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T09BU00559

Parcel: 123070130


Addresses:

2409 E MABEL ST

Inspection Status: Denied

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
05/26/2009 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) THERE IS NO APPARENT ROOF LEDGER ATTACHMENT TO HOUSE
2) PORCH AND DECK AREAS MORE THAN 30" ABOVE GRADE REQUIRE SAFETY RAILINGS AT LEAST 36" HIGH WITH NO OPENING GREATER THAN 4"
3) POST TO BEAM ATTACHMENTS ARE INSUFFICIENT
4) THERE IS NO APPARENT POST TO ROOF LEDGER ATTACHMENT
5) 2 X 6 RAFTERS ON 24" ON CENTER HAVE BEEN NOTCHED DOWN TO 4", WHICH IS INSUFFICIENT FOR A TILE ROOF LOAD
6) 4 X6 MID-SPAN BEAM OF 12' NEEDS AN ADDITIONAL POST
7) SUBMIT CORRECTIONS TO PLAN REVIEW
05/20/2009 BUILDING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) DOG LOOSE IN YARD
2) NO ACCESS
3) PLEASE RECALL