Permit: T08PL01778
Permit Details
Apply Date:
12/10/2008
Applicant:
STRANDBERG GRETCHEN
Description:
replace gas water heater
Contractors:
- ARIZONA PLUMBING SERVICES *C
Outstanding Activity Conditions
Permit Number - T08PL01778
Permit Status: Final
Permit Description: replace gas water heater
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/10/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T08PL01778
Permit Description: replace gas water heater
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2008 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A SEDIMENT TRAP AT GAS ENTRY TO APPLIANCE 2) GAS FLEXES ARE NOT TO BE REVERSED 3) PROVIDE PETITION OF APPEAL FORM SIGNED BY CITY OF TUCSON ON SITE AT TIME OF INSPECTION 4) PROVIDE A PLUG IN THE DRAIN PAN 5) PROVIDE A NIPPLE WITH NO THREADS ON DISCHARGE END OF 125# PRESSURE RELIEF DEVICE AT EXTERIOR 6) WHEN VENT FROM WATER HEATER IS WITHIN 10' OF COOLER INTAKE IT SHALL TERMINATE 3' ABOVE TOP OF COOLER INTAKE WITH APPROVED DBL WALL VENT PIPE AND CAP |
| 02/27/2009 | PERMIT FINALED | BFLORES | Approved |