Permit: T08PL01778

Parcel: 135111950


Addresses:

7624 E 30TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/26/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
12/29/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A SEDIMENT TRAP AT GAS ENTRY TO APPLIANCE
2) GAS FLEXES ARE NOT TO BE REVERSED
3) PROVIDE PETITION OF APPEAL FORM SIGNED BY CITY OF TUCSON ON SITE AT TIME OF INSPECTION
4) PROVIDE A PLUG IN THE DRAIN PAN
5) PROVIDE A NIPPLE WITH NO THREADS ON DISCHARGE END OF 125# PRESSURE RELIEF DEVICE AT EXTERIOR
6) WHEN VENT FROM WATER HEATER IS WITHIN 10' OF COOLER INTAKE IT SHALL TERMINATE 3' ABOVE TOP OF COOLER INTAKE WITH APPROVED DBL WALL VENT PIPE AND CAP