Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
10/17/2008
Applicant:
LEDEZMA MERCEDES
Description:
GAS LINE:REPAIR

Permit Reviews

Permit Number - T08PL01528
Permit Status: Expired
Permit Description: GAS LINE:REPAIR
Start Date Submittal Complete Date Status  
10/17/2008 PLUMBING 10/17/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08PL01528
Permit Status: Expired
Permit Description: GAS LINE:REPAIR
Total Outstanding Activity Conditions - 1
Date Name
10/17/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T08PL01528
Permite Description: GAS LINE:REPAIR
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/22/2008 PLUMBING - GAS PRESSURE TEST N/A Not ready for Inspection IVRS - Inspection :*
10/22/2008 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1. TEST TO HOLD WITH NO LOSS OF PRESSURE ON ENTIRE GAS SYSTEM
2. SCOTCH-COATED, PRIMED THEN TAPED PIPING AND FITTINGS IS REQUIRED FOR STEEL PIPING UNDERGROUND.
3. WATER HEATER TEMPERATURE & PRESSURE RELIEF IS REQUIRED TO GRAVITY DRAIN TO DAYLIGHT WITH APPROVED MATERIAL TERMINATING 6" TO 24" AT 90 DEG. DOWN (CPVC)
4. PROVIDE APPROVED GAS SHUTOFF VALVES AT ALL APPLIANCES AND AT BUILDING ENTRY IF METER IS IN ALLEY
5. PROVIDE DRIP LEGS AT FURNACE/WATER HEATER
6. PROVIDE BONDING OF BUILDING GAS PIPING

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW