Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Apply Date:
09/20/2008
Applicant:
WALTER VIRGINIA
Description:
Replace exsisting 40 gallon gas water heater.
Contractors:
  • RITE WAY VENTILATING CO , *C

Outstanding Activity Conditions

Permit Number - T08PL01396
Permit Status: Expired
Permit Description: Replace exsisting 40 gallon gas water heater.
Total Outstanding Activity Conditions - 1
Date Name
09/20/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T08PL01396
Permite Description: Replace exsisting 40 gallon gas water heater.
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/26/2008 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. MAKE UP VENT CONNECTOR TO DRAFT HOOD CORRECTLY AND PROVIDE FASTENERS
2. TEMPERATURE & PRESSURE RELIEF CANNOT BE COMBINED WITH CONDENSATE DRAINAGE, PROVIDE FULL SIZE T&P DRAIN PIPING GRAVITY DRAIN TO DAYLIGHT WITH 90 DEG. DOWN TERMINATION 6" TO 24" FROM FINISH GRADE.

Documents

File Name Document Type  
None DOCUMENTS VIEW