Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08PL01396
Permit Details
Apply Date:
09/20/2008
Applicant:
WALTER VIRGINIA
Description:
Replace exsisting 40 gallon gas water heater.
Contractors:
- RITE WAY VENTILATING CO , *C
Outstanding Activity Conditions
Permit Number - T08PL01396
Permit Status: Expired
Permit Description: Replace exsisting 40 gallon gas water
heater.
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/20/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08PL01396
Permite Description: Replace exsisting 40 gallon gas water
heater.
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2008 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MAKE UP VENT CONNECTOR TO DRAFT HOOD CORRECTLY AND PROVIDE FASTENERS 2. TEMPERATURE & PRESSURE RELIEF CANNOT BE COMBINED WITH CONDENSATE DRAINAGE, PROVIDE FULL SIZE T&P DRAIN PIPING GRAVITY DRAIN TO DAYLIGHT WITH 90 DEG. DOWN TERMINATION 6" TO 24" FROM FINISH GRADE. |