Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
Permit Number - T08PL01396
Inspection Description - PLUMBING - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MAKE UP VENT CONNECTOR TO DRAFT HOOD CORRECTLY AND PROVIDE FASTENERS 2. TEMPERATURE & PRESSURE RELIEF CANNOT BE COMBINED WITH CONDENSATE DRAINAGE, PROVIDE FULL SIZE T&P DRAIN PIPING GRAVITY DRAIN TO DAYLIGHT WITH 90 DEG. DOWN TERMINATION 6" TO 24" FROM FINISH GRADE. |