Permit Details

Status:
C of o
Type:
MULTI FAMILY OTHER
Address:
1701 N PARK AV
Address NEW:
1701 N PARK AV
Apply Date:
09/05/2008
Applicant:
BETSEY PARLATO
Description:
SUPERVISED LIVING APARTMENT COMPLEX

Permit Reviews

Permit Number - T08OT02108
Permit Status: C of o
Permit Description: SUPERVISED LIVING APARTMENT COMPLEX
Start Date Submittal Complete Date Status  
04/20/2009 C OF O 04/20/2009 COMPLETED Review Details
09/05/2008 C OF O 09/09/2008 COMPLETED Review Details
09/09/2008 OTHER 09/22/2008 COMPLETED Review Details
12/30/2008 C OF O 12/30/2008 COMPLETED Review Details
12/30/2008 RESUBMITTAL 01/07/2009 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T08OT02108
Permit Description: SUPERVISED LIVING APARTMENT COMPLEX
Total Completed Inspections - 6
Date Description Inspector Results Comments
09/23/2008 FIRE - FINAL RDAVIS Approved I-1 NEED TO BE SPRINKLERED
09/23/2008 SIGN - FINAL JYBARRA Approved NO SIGN ON SITE
09/24/2008 CERTIFICATE OF OCCUPANCY LHANLY Approved THE NEW USE OF THIS BUILDING CONSTITUTES A CHANGE OF OCCUPANCY. THEREFORE THIS COMPLEX WILL NEED TO BE SPRINKLERED PER THE INTERNATIONAL FIRE CODE. ALSO ELEMENTS THAT ARE NOW USED DIFFERENTLY THAN THE ORIGINAL R-2 DESIGNATION WILL NEED TO COMPLY WITH SECTION 3409.4 ACCESSIBILITY REQUIREMENTS OF THE 2006 IBC. TO WIT:

a) ALL COMMON ROOM DOORS (office, adjunct office, laundry, and "classrooms") SHALL HAVE LEVER HANDLE HARDWARE THAT UNLOCKS FROM THE EGRESS SIDE WHEN THE HANDLE IS TURNED, AND SHALL REQUIRE NO MORE THAN 5lbs OF FORCE TO OPEN.
b) LANDINGS LEVEL WITH THE INTERIOR FLOOR SHALL BE REQUIRED AT THE EXTERIOR OF THE LAUNDRY, OFFICE AND 1ST FLOOR CLASSROOM. THRESHOLDS SHALL NOT EXCEED 3/4" IN HEIGHT.
c) AN ACCESSIBLE PARKING SPACE SHALL BE REQUIRED, WITH AN ACCESS AISLE IN THE SOUTH-WEST PARKING LOT.

ALSO
1) LABEL THE SPACE MARKED "OFFICE" ON PLANS AS ADJUNCT OFFICE AS IT HAS NO PLUMBING FACILITIES.
2) LABEL APT. 8 MARKED ON PLANS AS "OFFICE". THIS WAY YOU WILL NOT NEED TO PROVIDE A NEW RESTROOM FOR #1 ABOVE.
3) POST A 12" ADDRESS DISPLAY PER PIMA COUNTY ZONING ORDINANCE.
4) CAP UNUSED DRAIN IN THE LAUNDRY.
5) DO NOT STORE ITEMS NEXT TO OR IMMEDIATLY ON TOP OF WATER HEATER IN STORE ROOM.
6) LABEL ALL ELECTRIC CIRCUITS IN ALL SERVICE PANELS, INCLUDING STORE ROOM.
7) ANTI-TIP DEVICES WILL BE REQUIRED ON ALL STOVES.
8) FINISH REPAIRING ALL HOLES IN CEILINGS AND WALLS BEFORE UNITS ARE OCCUPIED.
9) CAULK ALL TOILETS AT FLOOR AND ALL LAVATORIES & SINKS AT THE COUNTER AND WALL.
05/14/2009 FIRE SPKLR - UG, PIPING, HYDRO RSPANGLE Approved
05/14/2009 FIRE SPKLR - FINAL RSPANGLE Approved SEE T09BU00100
05/15/2009 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
PROVISIONAL CERT OF OCC.TIF CERT OF OCC VIEW
TEMP C OF O_12-12-2008.TIF CERT OF OCC VIEW
C OF O_05-15-2009.TIF CERT OF OCC VIEW
None DOCUMENTS VIEW
001_CVR.TIF DOCUMENTS VIEW
002_C-1.TIF DOCUMENTS VIEW
003_C-2.TIF DOCUMENTS VIEW
004_A-1.TIF DOCUMENTS VIEW
005_A-2.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW