Permit: T08OT01399
Permit Details
Apply Date:
06/11/2008
Applicant:
DELPH, KENT ALAN
Description:
FLOODPLAIN USE PERMIT
Permit Reviews
Permit Number - T08OT01399
Permit Status: Issued
Permit Description: FLOODPLAIN USE PERMIT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/11/2008 | PLANS OK TO SUBMIT - FLOODPLAIN | 06/11/2008 | COMPLETED |
| 06/11/2008 | FLOODPLAIN | 12/16/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08OT01399
Permit Status: Issued
Permit Description: FLOODPLAIN USE PERMIT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/21/2008 | August 21, 2008 FLOODPLAIN USE PERMIT # T08OT01399 PROJECT ADDRESS: 665 N Freeway Rd, Tucson Arizona 85706 APPLICANT'S NAME: GDA & Associates (Chuck Schuiteman, RA) PROPERTY OWNER: Eastgroup Properties This parcel lies in a FEMA 500-year Zone X-shaded (map number 040076 C 2226K). The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: Parcel 116-16-301G, 665 N Freeway, COUNTRY, 5.20 AC PTN OF LOTS 13 & 14 LYG W OF I-10 & N OF ST MARYS RD in a portion of Township 14 South, Range 13 East, Section 11, for the purpose of drainage improvements and associated development construction for Country Inn & Suites hotel project. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 11 conditions apply to permit T08OT01399: 1) Call for Pre-construction meeting, elevation certification inspections, and final inspections. For a DSD Engineering Inspection, call IVR (740-6970), or contact DSD Engineering at 837-4991, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 2) DSD Engineering Inspections are required prior to SWPPP installation, completion of the drainage improvements, and final floodplain inspection. 3) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT01399. FOR INFORMATION PLEASE CALL 791-5550." 4) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 5) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 6) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 7) Designated concrete washout locations are required and shall not be located in or near water harvesting areas. Location of temporary material or vehicle staging / stockpile area shall be placed within grading limits and not located in any water harvesting or floodplain areas. 8) All work shall conform to the approved Third Submittal Drainage Report Country Inn & Suites sealed by Kent Delph, PE (7.29.8), and the Geotechnical Engineering Report prepared by Terracon, sealed by Brent Borchers (11/16/07), as well as the approved Private Improvement, Grading & Paving Plans for Country Inn & Suites project, which is made part of this permit. 9) See the associated grading plan T08BU00131 and the approved building plans T08CM00263. 10) Disturbance of the floodplain is only permitted as per the approved construction plans. There shall be no wash off area, temporary chemical storage area, temporary refuse area, or other construction storage within the floodplain areas as shown on the plans and as determined by the Drainage Report. 11) Any wash off area, temporary chemical storage area, temporary refuse area, and / or vehicle storage areas shall be placed in non-floodplain areas and shall have interim stormwater controls installed along downstream side of these areas. Downstream side of the road construction area shall also have interim erosion and sediment controls installed and maintained until all disturbed areas are constructed. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire two year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 8 Day: 22 Year: 2010 APPLICANT: Grenier Engineering (Kent Delph PE) ADDRESS: 5517 E 5th Street, Tucson Arizona 85711 PHONE: (520) 326-7082 OWNER: HIMADA PROPERTIES LLC ADDRESS: 1442 E LINCOLN AVE #444, ORANGE CA 92865 PHONE: 622-6491 (Contact Person: Jeff Trask) |