Permit: T08EL02012
Permit Details
Apply Date:
10/22/2008
Applicant:
BRENT MCMILLAN
Description:
ELECTRICAL RECONNECT
Outstanding Activity Conditions
Permit Number - T08EL02012
Permit Status: Expired
Permit Description: ELECTRICAL RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/22/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08EL02012
Permite Description: ELECTRICAL RECONNECT
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2008 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 10/23/2008 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROTECT ALL ROMEX IN LAUNDRY UNDER 7' 2) MISSING COVER PLATES LAUNDRY 3) PROVIDE PROOF PERMIT 220 ADDED TO LAUNDRY ROOM HAZARDOUS NOT TO CODE 4) REMOVE ELECTRICAL FROM STORAGE ROOMS OR PERMIT HAZARDOUS ELECTRICAL TO STORAGE AT OVERHANG STORAGE ROOMS TO CLOSE TO PROPERTY LINES 5) REMOVE ALL CIRCUITS FROM 100 AMP METER DISCONNECT 6) REMOVE ADDED ROMEX AND LIGHT FIXTURES TO REAR PORCH OR PERMIT NOT TO CODE 7) REMOVE FRONT LIGHT FIXTURE OR PERMIT, NOT TO CODE 8) PROVIDE PROOF GARAGE ENCLOSURE TO ROOM PERMITTED 9) GFCI PROTECT KITCHEN COUNTER OUTLETS AND BATHS 10) SMOKE DETECTORS BEDROOMS 11) ALL BEDROOM BARS MUST RELEASE WITHOUT TOOLS |