Permit: T08EL02012

Parcel: 138191360


Addresses:

6707 S LUNDY AV

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/23/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROTECT ALL ROMEX IN LAUNDRY UNDER 7'
2) MISSING COVER PLATES LAUNDRY
3) PROVIDE PROOF PERMIT 220 ADDED TO LAUNDRY ROOM HAZARDOUS NOT TO CODE
4) REMOVE ELECTRICAL FROM STORAGE ROOMS OR PERMIT HAZARDOUS ELECTRICAL TO STORAGE AT OVERHANG STORAGE ROOMS TO CLOSE TO PROPERTY LINES
5) REMOVE ALL CIRCUITS FROM 100 AMP METER DISCONNECT
6) REMOVE ADDED ROMEX AND LIGHT FIXTURES TO REAR PORCH OR PERMIT NOT TO CODE
7) REMOVE FRONT LIGHT FIXTURE OR PERMIT, NOT TO CODE
8) PROVIDE PROOF GARAGE ENCLOSURE TO ROOM PERMITTED
9) GFCI PROTECT KITCHEN COUNTER OUTLETS AND BATHS
10) SMOKE DETECTORS BEDROOMS
11) ALL BEDROOM BARS MUST RELEASE WITHOUT TOOLS