Permit: T08EL01960
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
401 E FORT LOWELL RD #01
Address NEW:
401 E FORT LOWELL RD #01
Apply Date:
10/14/2008
Applicant:
ANTONIO AGUILAR
Description:
ELECTRIC:RECONNECT RESIDENCE
Outstanding Activity Conditions
Permit Number - T08EL01960
Permit Status: Final
Permit Description: ELECTRIC:RECONNECT RESIDENCE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/14/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T08EL01960
Permit Description: ELECTRIC:RECONNECT RESIDENCE
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2008 | ELECTRIC - FINAL | RHOLLAND | Approved | - OLD RESIDENCE GOING TO BE GRANITE COUNTERTOP COMPANY OUTSIDE: 1. CAP WIRES AND COVER BOXES EXPOSED CONDUCTORS 2. PROPERLY ATTACH FIXTURE TO BOX 3. SUPPORT BOXES & CONDUIT TO STRUCTURE 4. BOXES TO BE FOR WET LOCATION & COVERS 5. SECURE GROUNDING ELECTRODE CONDUCTOR TO STRUCTURE 6. ADDRESS LABEL TO BE PERMANENT 7. PLEASE VERIFY GAS & WATER BONDS INTERIOR: 1. PLEASE VERIFY PERMITS FOR NEW WIRING INSIDE 2. ONLY ONE CONDUCTOR PER TERMINAL SCREW 3. GROUND DEVICES 4. USE APPROVED HARDWARE FOR DEVICES - NOT DRYWALL SCREWS 5. EXPOSED CONDUCTOR & NO BOXES 6. GROUNDED RECEPTACLES ON UNGROUND WIRING 7. BOXES MORE THAN 1/4" FROM BOX TO SURFACE *QUALIFIED ELECTRICIAN MUST DO WORK |
| 05/21/2009 | ELECTRIC - RECONNECT | DSANTACR | Approved | IVRS - Inspection :* |
| 05/22/2009 | PERMIT FINALED | JWEATHER | Approved | |
| 05/22/2009 | TEP CLEARANCE - AM | JWEATHER | Approved | RECN CLEARED FOR #1 PER D. SANTACRUZ |