Permit: T08EL01960

Parcel: 106042910

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/21/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
10/16/2008 ELECTRIC - FINAL Denied - OLD RESIDENCE GOING TO BE GRANITE
COUNTERTOP COMPANY

OUTSIDE:
1. CAP WIRES AND COVER BOXES EXPOSED CONDUCTORS
2. PROPERLY ATTACH FIXTURE TO BOX
3. SUPPORT BOXES & CONDUIT TO STRUCTURE
4. BOXES TO BE FOR WET LOCATION & COVERS
5. SECURE GROUNDING ELECTRODE CONDUCTOR TO STRUCTURE
6. ADDRESS LABEL TO BE PERMANENT
7. PLEASE VERIFY GAS & WATER BONDS

INTERIOR:
1. PLEASE VERIFY PERMITS FOR NEW WIRING INSIDE
2. ONLY ONE CONDUCTOR PER TERMINAL SCREW
3. GROUND DEVICES
4. USE APPROVED HARDWARE FOR DEVICES - NOT DRYWALL SCREWS
5. EXPOSED CONDUCTOR & NO BOXES
6. GROUNDED RECEPTACLES ON UNGROUND WIRING
7. BOXES MORE THAN 1/4" FROM BOX TO SURFACE

*QUALIFIED ELECTRICIAN MUST DO WORK