Outstanding Activity Conditions
Permit Number - T08EL01798
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC MH
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/15/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08EL01798
Permite Description: RECONNECT:ELECTRIC MH
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/16/2008 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 09/16/2008 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BEDROOMS REQUIRE SMOKIES 2) KITCHEN COUNTER RECEPTACLES MUST BE GFI PROTECTED 3) NEED TO BOND GAS LINE 4) NEED TO USE APPROVED PIPING FOR TPR LINE AT WATER HEATER NOT PVC 5) WILL NEED A SEDIMENT TRAP AT GAS LINE WATER HEATER 6) NEED TO ADD GFI RECEPTACLE AT MASTER BATH FOR DBL LAVS 7) NEED HIGH/LOW COMBUSTION AIR AT WATER HEATER 8) NEED TO REPAIR OUTSIDE GFI RECEPTACLE COVER S.W. CORNER |