Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
7241 E MARIGOLD CI
Apply Date:
07/15/2008
Applicant:
ORNELAS PAUL A
Description:
ELECTRICAL RECONNECT

Outstanding Activity Conditions

Permit Number - T08EL01318
Permit Status: Closed
Permit Description: ELECTRICAL RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
07/15/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T08EL01318
Permite Description: ELECTRICAL RECONNECT
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
PERMIT FINALED N/A Not Inspected
09/16/2008 ELECTRIC - FINAL N/A Not ready for Inspection IVRS - Inspection :*
1) NEED 15 AMP BREAKERS FOR 2-#14 WIRES TOP RIGHT IN PANEL
2) GARAGE OUTLETS TO BE GFI PROTECTED
3) CORRECT DRYER VENT RUN
4) RECALL FOR FINAL AFTER RECONNECT

Completed Inspections

Permit Status: Closed
Permit Number: T08EL01318
Permit Description: ELECTRICAL RECONNECT
Total Completed Inspections - 2
Date Description Inspector Results Comments
09/16/2008 ELECTRIC - RECONNECT DQUINN Approved IVRS - Inspection :*
09/17/2008 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER D. QUINN

Documents

File Name Document Type  