Permit: T08EL01318

Parcel: 136383210


Addresses:

7241 E MARIGOLD CI

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
09/16/2008 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
08/26/2008 ELECTRIC - RECONNECT Denied 1) SERVICE PANEL NEEDS TO BE CLEANED UP
2) BREAKERS OVER SIZED FOR WIRE, LABEL CIRCUITS
3) REMOVE WIRING IN GARAGE OR BRING UP TO CODE
4) WIRING ON ROOF TO BE IN RIGID CONDUIT SUPPORTED ON BLOCKS
5) ADDITION ON EAST SIDE TO BE PERMITTED, BUILT WITH PERMIT
6) ADDITION AT REAR PORCH, FAMILY ROOM
7) INSTALL LIGHT FIXTURES OR BLANK OFF
8) SMOKE DETECTOR IN EACH BEDROOM ONE IN HALLWAY
9) GFCI RECEPT AT KITCHEN COUNTER
10) WHERE IS JACUZZI ACCESS PANEL SHOULD BE ON IT'S OWN CIRCUIT
08/21/2008 ELECTRIC - RECONNECT Not ready for Inspection IVRS - Inspection :*