Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
7787 S KILCORMAC LN
Apply Date:
06/09/2008
Applicant:
RICHARD & MARIA GIL
Description:
ELECTRIC:RECONNECT RESIDENCE

Outstanding Activity Conditions

Permit Number - T08EL01033
Permit Status: Final
Permit Description: ELECTRIC:RECONNECT RESIDENCE
Total Outstanding Activity Conditions - 1
Date Name
06/09/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T08EL01033
Permit Description: ELECTRIC:RECONNECT RESIDENCE
Total Completed Inspections - 4
Date Description Inspector Results Comments
06/27/2008 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. EXPOSED ROMEX AT OVEN EXHAUST FAN,
RECEPT NOT IN A BOX
2. ADDITION IN REAR, RAMADA, STOREROOM SHED TYPE ATTACHED STRUCTURE
3. SOURCE OF WIRING FOR ADDITION? AC TO BE ON ITS OWN CIRCUIT, LIGHTING CIRCUIT SOURCE?
4. GARAGE ROMEX TERMINATED WITH WIRE NUTS, NOT IN A BOX, STRUCT. OUT OF DRYWALL. WHAT IS IT FOR?
5. ROMEX CUT AT WEST WALL GARAGE ROMEX COMING FROM OUTSIDE
6. ZIP CHORD RUN IN GARAGE OPEN SPLICES
7. WATER HTR. FLUE INSTALLED INCORRECTLY ALSO T&P LINE TWO FLEX CONNECTORS USED TO INCORRECTLY
8. MSTR. CLOSET EXPOSED LIGHT BULB
9. UNLISTED GAS APPLIANCE IN F/PLACE, REMOVE COMBUSTIBLE MANTLE
10. LOOSE LIGHT FIXTURE 2ND FLR CLOSET
11. 2ND FLR RELIEF DUCT BLKD OFF CHECK COMB. DUCT
12. ALL EXT. OUTLETS TO BE GFCI PROTECTED, WITH A WEATHER TIGHT COVER
13. TWO POLE 15 AMP BREAKER LABEL SPA, WIRES LOOSE, SPA?
11/25/2008 ELECTRIC - RECONNECT RFREIDIN Approved IVRS - Inspection :*
1) FINISH ALL DEMO AND RECALL FINAL
11/26/2008 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER R. FREIDINGER
01/26/2009 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW