Permit: T08EL01033

Parcel: 141143320


Addresses:

7787 S KILCORMAC LN

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/21/2009 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/20/2009 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COVER PLATES NEEDED FOR OUTLETS IN LAUNDRY AND GARAGE
2) #6 UNABLE TO LOCATE
3) #7 STILL INSTALLED PER PREVIOUS INSPECTION
4) HANDLE NEEDED FOR VALVE ON GAS FOR FURNACE
06/27/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. EXPOSED ROMEX AT OVEN EXHAUST FAN,
RECEPT NOT IN A BOX
2. ADDITION IN REAR, RAMADA, STOREROOM SHED TYPE ATTACHED STRUCTURE
3. SOURCE OF WIRING FOR ADDITION? AC TO BE ON ITS OWN CIRCUIT, LIGHTING CIRCUIT SOURCE?
4. GARAGE ROMEX TERMINATED WITH WIRE NUTS, NOT IN A BOX, STRUCT. OUT OF DRYWALL. WHAT IS IT FOR?
5. ROMEX CUT AT WEST WALL GARAGE ROMEX COMING FROM OUTSIDE
6. ZIP CHORD RUN IN GARAGE OPEN SPLICES
7. WATER HTR. FLUE INSTALLED INCORRECTLY ALSO T&P LINE TWO FLEX CONNECTORS USED TO INCORRECTLY
8. MSTR. CLOSET EXPOSED LIGHT BULB
9. UNLISTED GAS APPLIANCE IN F/PLACE, REMOVE COMBUSTIBLE MANTLE
10. LOOSE LIGHT FIXTURE 2ND FLR CLOSET
11. 2ND FLR RELIEF DUCT BLKD OFF CHECK COMB. DUCT
12. ALL EXT. OUTLETS TO BE GFCI PROTECTED, WITH A WEATHER TIGHT COVER
13. TWO POLE 15 AMP BREAKER LABEL SPA, WIRES LOOSE, SPA?