Permit: T08CM03152
Permit Details
Apply Date:
09/22/2008
Applicant:
N/A
Description:
TI:RETAIL
Architects:
- NIELSEN, TIM RICHARD
Contractors:
- FARNSWORTH CONSTRUCTION COMPANY
Permit Reviews
Permit Number - T08CM03152
Permit Status: Expired
Permit Description: TI:RETAIL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/22/2008 | COMMERCIAL TI | 09/24/2008 | COMPLETED |
09/24/2008 | COMMERCIAL TI | 09/24/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM03152
Permit Status: Expired
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/22/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Expired
Permit Number: T08CM03152
Permit Description: TI:RETAIL
Total Completed Inspections - 13
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/18/2008 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* SOFFIT FRAMING OK |
12/05/2008 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* OK ROLL DOOR WALL |
12/08/2008 | FIRE - FINAL | MWAINWRI | Approved | Partial - OK for temp C of O |
12/08/2008 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1-480-790-7549 IS A NON-WORKING NUMBER UNABLE TO LOCATE PERMIT CARD NO ACCESS TO STOREROOM, OR ACCESSIBLE RESTROOM CONTINUED "NOT READY" MAY RESULT IN REINSPECTION FEE REINSPECTED - LOOKED AT EXISTING ACCESSIBLE RESTROOM OK -- NO PLUMBING ON THIS PERMIT. |
12/08/2008 | PLUMBING - INTERMEDIATE | RMYERS | Approved | |
12/09/2008 | ENGINEERING - FINAL | MRUSSO | Approved | |
12/10/2008 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
12/10/2008 | NPPO - FINAL | ACONNOR | Approved | N/A |
12/10/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
12/15/2008 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* NEXT INSPECTION AFTER CASH WRAP MOVE *NOTE: 725.24, 800.24, 300.11 WILL APPLY FOR VDV CABLING ABOVE CEILING 1. FINISH LABELING CI. 12 & 19 & 23 & 25 & 28 -- NO ABBREVIATIONS |
12/15/2008 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* OK TEMP C OF O |
12/15/2008 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
12/28/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved |