Permit: T08CM03112
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
865 W ILLINOIS ST
Address NEW:
865 W ILLINOIS ST
Apply Date:
09/16/2008
Applicant:
N/A
Description:
ENCLOSE:REAR PORCH TO ROOM T08DV06569
Permit Reviews
Permit Number - T08CM03112
Permit Status: Final
Permit Description: ENCLOSE:REAR PORCH TO ROOM T08DV06569
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/16/2008 | RESIDENTIAL BLDG/ZONING-WALKTHRU | 09/25/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM03112
Permit Status: Final
Permit Description: ENCLOSE:REAR PORCH TO ROOM T08DV06569
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/16/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T08CM03112
Permit Description: ENCLOSE:REAR PORCH TO ROOM T08DV06569
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/02/2008 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE LETTERHEAD LICENSED ELECTRICAL CONTRACTOR TO VERIFY WORK TO CODE OR EXPOSE STOPPED INSPECTION 1. POST HOUSE NUMBERS 2. EXPOSE FOOTERS VERIFY DEPTH 3. PROVIDE COMBUSTION RELIEF WH TO EXTERIOR EXTEND RELIEF VALVE TO EXTERIOR OR PAN 4. OVERNOTCHED 6" X 8" BEAM AT EXTERIOR DOOR 5. STOOP KITCHEN DOOR 6. EXPOSE TREATED PLATES 7. PROVIDE PROOF REBAR SCHEDULE MASONRY PER PLAN VERTS AND BOND BEAMS 8. WRONG FASTENERS H2.5 CLIPS 9. PLAN CALLS FOR 2X8 RAFTERS 2X6 INSTALLED 10. MISSING 18" FHA STRAPS @ COLUMNS PER PLAN 11. MISSING HARDWIRED BASEBOARD HEATERS 12. MISSING HARDWIRED SMOKE DETECTORS 13. MISSING OUTLET @ PANTRY WALL 14. LIGHT FIXTURE WITHIN 12" CLOSET SHELF COMBUSTIBLES |
| 12/02/2008 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/02/2008 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 08/17/2011 | SHEET ROCK NAILING | DWALKER | Approved | IVRS - Inspection :* |
| 08/17/2011 | FRAMING | DWALKER | Approved | IVRS - Inspection :* |
| 08/17/2011 | MECHANICAL - INTERMEDIATE | DWALKER | Approved | IVRS - Inspection :* |
| 08/17/2011 | ELECTRIC - INTERMEDIATE | DWALKER | Approved | IVRS - Inspection :* |
| 08/17/2011 | EXT METAL CLIPS/EXT SHEATHING | DWALKER | Approved | IVRS - Inspection :* |
| 08/17/2011 | REINFORCED MASONRY PRE-GROUT | DWALKER | Approved | IVRS - Inspection :* |
| 08/17/2011 | BUILDING PRE-SLAB | DWALKER | Approved | IVRS - Inspection :* |
| 08/17/2011 | STEM WALL/RETAINING WALL | DWALKER | Approved | IVRS - Inspection :* |
| 08/17/2011 | EXCAVATION/LAYOUT REBAR & ZON | DWALKER | Approved | IVRS - Inspection :* |