Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2012 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 02/09/2012 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/17/2011 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 08/20/2010 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS FROM PREVIOUS INSPECTION NOT COMPLIED WITH #0 LETTER FROM LICENSED ELECTRICIAN ON WIRING 2) #3 COMBUSTION RELIEF WH TO EXTERIOR OR PAN 3) #4 OVER KNOTCHED BEAM AT EXTERIOR DOOR AND PROPERLY TIE IN BEAM 4) #9 PLANS CALL FOR 2 X 8 RAFTERS OR CHANGE PLAN 5) #14 REMOVE WIRING TO CLOSET LIGHT IF NOT USING ALL THE WAY TO PANEL 6) NEED TO FINISH ALL ITEMS FROM PREVIOUS LIST |
|
| 02/22/2010 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/02/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE LETTERHEAD LICENSED ELECTRICAL CONTRACTOR TO VERIFY WORK TO CODE OR EXPOSE STOPPED INSPECTION 1. POST HOUSE NUMBERS 2. EXPOSE FOOTERS VERIFY DEPTH 3. PROVIDE COMBUSTION RELIEF WH TO EXTERIOR EXTEND RELIEF VALVE TO EXTERIOR OR PAN 4. OVERNOTCHED 6" X 8" BEAM AT EXTERIOR DOOR 5. STOOP KITCHEN DOOR 6. EXPOSE TREATED PLATES 7. PROVIDE PROOF REBAR SCHEDULE MASONRY PER PLAN VERTS AND BOND BEAMS 8. WRONG FASTENERS H2.5 CLIPS 9. PLAN CALLS FOR 2X8 RAFTERS 2X6 INSTALLED 10. MISSING 18" FHA STRAPS @ COLUMNS PER PLAN 11. MISSING HARDWIRED BASEBOARD HEATERS 12. MISSING HARDWIRED SMOKE DETECTORS 13. MISSING OUTLET @ PANTRY WALL 14. LIGHT FIXTURE WITHIN 12" CLOSET SHELF COMBUSTIBLES |