Permit: T08CM03112

Parcel: 120050950


Addresses:

865 W ILLINOIS ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/06/2012 BUILDING - FINAL Approved IVRS - Inspection :*
02/09/2012 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
08/17/2011 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
08/20/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS FROM PREVIOUS INSPECTION NOT COMPLIED WITH #0 LETTER FROM LICENSED ELECTRICIAN ON WIRING
2) #3 COMBUSTION RELIEF WH TO EXTERIOR OR PAN
3) #4 OVER KNOTCHED BEAM AT EXTERIOR DOOR AND PROPERLY TIE IN BEAM
4) #9 PLANS CALL FOR 2 X 8 RAFTERS OR CHANGE PLAN
5) #14 REMOVE WIRING TO CLOSET LIGHT IF NOT USING ALL THE WAY TO PANEL
6) NEED TO FINISH ALL ITEMS FROM PREVIOUS LIST
02/22/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/02/2008 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE LETTERHEAD LICENSED ELECTRICAL CONTRACTOR TO VERIFY WORK TO CODE OR EXPOSE

STOPPED INSPECTION

1. POST HOUSE NUMBERS
2. EXPOSE FOOTERS VERIFY DEPTH
3. PROVIDE COMBUSTION RELIEF WH TO EXTERIOR EXTEND RELIEF VALVE TO EXTERIOR OR PAN
4. OVERNOTCHED 6" X 8" BEAM AT EXTERIOR DOOR
5. STOOP KITCHEN DOOR
6. EXPOSE TREATED PLATES
7. PROVIDE PROOF REBAR SCHEDULE MASONRY PER PLAN VERTS AND BOND BEAMS
8. WRONG FASTENERS H2.5 CLIPS
9. PLAN CALLS FOR 2X8 RAFTERS 2X6 INSTALLED
10. MISSING 18" FHA STRAPS @ COLUMNS PER PLAN
11. MISSING HARDWIRED BASEBOARD HEATERS
12. MISSING HARDWIRED SMOKE DETECTORS
13. MISSING OUTLET @ PANTRY WALL
14. LIGHT FIXTURE WITHIN 12" CLOSET SHELF COMBUSTIBLES