Permit: T08CM02682
Permit Details
Apply Date:
08/04/2008
Applicant:
N/A
Description:
TI: MCDONALDS
Architects:
- GOGLIA, FREDERICK J
Contractors:
- FLEMING COMPLETE
Permit Reviews
Permit Number - T08CM02682
Permit Status: Final
Permit Description: TI: MCDONALDS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/04/2009 | REVISION - - 1ST | 07/30/2009 | COMPLETED |
07/30/2009 | REVISION - - 1ST | 07/30/2009 | COMPLETED |
08/04/2008 | PLANS OK TO SUBMIT - COMM | 08/04/2008 | COMPLETED |
08/05/2008 | COMMERCIAL TI | 09/15/2008 | COMPLETED |
09/15/2008 | RESUBMITTAL | 10/01/2008 | COMPLETED |
10/01/2008 | RESUBMITTAL | 10/22/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM02682
Permit Status: Final
Permit Description: TI: MCDONALDS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/04/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T08CM02682
Permit Description: TI: MCDONALDS
Total Completed Inspections - 15
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/30/2008 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* WATER PIPING OK WILL SEE FINAL VENT CONNECTION AT FINAL |
10/30/2008 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* WATER TEST TO ABOVE CEILING OK |
10/31/2008 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
11/02/2008 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* SEAL OPEN KNOCKOUT IN RECEPT BOX THEN OK CASH REGISTER PONY WALL |
11/04/2008 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
11/10/2008 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* 1. MS FAUCET HAS NO VAC BREAKER AND AN IMPROPER SOAP DISP. CONN. 2. PROVIDE BACKFLOW PROTECTION AS SPECIFIED ON P100 3. INSTALL/RELOCATE EQUIPMENT AS SPECIFIED |
11/10/2008 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection :* |
11/19/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALLATION NOT PER PLANS. INSTALL PER PLANS OR REVISE PLANS 2. STRAP MC CABLE WITHIN 12" OF CONNECTIONS AND EVERY 6' BETWEEN. NOT TO LAY ON CEILING 3. REMOVE OLD WIRING 4. GROUND METAL BOXES 5. SEAL OPEN KNOCKOUTS 6. JUNCTION BOXES OVERFILLED. NEED 6" OF FREE CONDUCTOR LENGTH 7. USE CONNECTORS ON MC WHERE ENTER EQUIPMENT OR RACEWAYS 8. RE-IDENTIFY WHITE WIRES USED AS PHASE CONDUCTORS 9. NEED UPDATED PANEL SCHEDULES 10. WHERE ARE ALL NEW CIRCUITS SHOWN ON PLANS 11. SEE NOTE 7 ON PLANS FOR GFI PROTECTION 12. ELECTRICAL CONTRACTOR TO INSTALL PER PLANS & NEC |
11/19/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* NEED ELEC & PLUMBING FINALS BEFORE BLDG. FINAL |
11/19/2008 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
11/19/2008 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* |
11/19/2008 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
11/19/2008 | FIRE - FINAL | LTHOMAS | Approved | |
04/28/2009 | SIGN - FINAL | JYBARRA | Approved | |
08/07/2009 | PERMIT FINALED | JWEATHER | Approved |