Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08CM01831
Permit Details
Apply Date:
06/03/2008
Applicant:
N/A
Description:
NEW: APARTMENT BUILDING #6
Contractors:
- K AND S II LIMITED ,
Permit Reviews
Permit Number - T08CM01831
Permit Status: C of o
Permit Description: NEW: APARTMENT BUILDING #6
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
06/03/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 06/03/2008 | COMPLETED |
06/03/2008 | 3RD PARTY REVIEW-COMMERCIAL | 09/08/2008 | COMPLETED |
09/08/2008 | POST 3RD PARTY REVIEW | 10/06/2008 | COMPLETED |
12/15/2008 | RESUBMITTAL | 04/07/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM01831
Permit Status: C of o
Permit Description: NEW: APARTMENT BUILDING #6
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/03/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM01831
Permit Description: NEW: APARTMENT BUILDING #6
Total Completed Inspections - 44
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/24/2009 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* |
08/04/2009 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* 1) POST TENSION SYSTEM-OK TO POUR |
08/04/2009 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* 1) OK TO POUR CONTINOUS FOOTINGS |
08/04/2009 | ELECTRIC - UFER | RMORENO | Approved | IVRS - Inspection :* 1) UFER AT BLDG 6-OK |
08/04/2009 | ELECTRIC - UNDERGROUND | RMORENO | Approved | IVRS - Inspection :* |
09/01/2009 | ROOF NAILING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO DRY IN |
09/02/2009 | EXT METAL CLIPS/EXT SHEATHING | JBURGE | Approved | IVRS - Inspection :* 1) SHEATHING & METAL CLIPS AND STRAPS |
09/09/2009 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* DWV AND WATER TESTS OK TUBS OK OK TO COVER RECALL FOR CLOSET FURNACE INSP AFTER FF |
09/11/2009 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
09/15/2009 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR PRE-ROCK |
10/02/2009 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* |
10/07/2009 | ELECTRIC - ABOVE CEILING | RMORENO | Approved | IVRS - Inspection :* 1) CEILING FOR A/C DUCT ONLY OK |
10/16/2009 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR SHEETROCK |
10/29/2009 | PLUMBING - PROGRESS | BBENEDON | Approved | IVRS - Inspection :* |
11/02/2009 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* |
11/06/2009 | ELECTRIC - INTERMEDIATE | RMORENO | Approved | IVRS - Inspection :* 1) SERVICE WIRES, WALLS AND CEILINGS OK |
11/09/2009 | FRAMING | JBURGE | Approved | IVRS - Inspection :* 1) 1ST & 2ND FLOOR COMPLETE-OK TO SHEETROCK PENDING PLUMBING AND ELECTRIC INTERMEDIATES |
11/09/2009 | U VALUE FOR WINDOW | JBURGE | Approved | IVRS - Inspection :* |
11/09/2009 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* |
11/13/2009 | ELECTRIC - CABLE DROP | RMORENO | Approved | 1) LADERAL TO METER BASE OK |
11/25/2009 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* 1) OK TO TAPE THROUGHOUT |
11/30/2009 | BUILDING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* 1) STAIR FOOTING-OK TO POUR FOOTING |
12/15/2009 | ELECTRIC - TEMPORARY SERVICE | JJAWORSKY | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1) MUST POST BOND FIRST |
12/28/2009 | STUCCO MESH | MHENSON | Approved | IVRS - Inspection :* |
03/26/2010 | ELECTRIC - TEMP POWER FOR TEST | RMORENO | Approved | IVRS - Inspection :* |
03/29/2010 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED FOR 1ST FLOOR: 6101,6102,6103 & 6104 AND FOR 2ND FLOOR: 6201,6202,6203 & 6204 PER R. MORENO |
04/19/2010 | SIGN - FINAL | JYBARRA | Approved | |
04/27/2010 | NPPO - FINAL | ACONNOR | Approved | |
05/03/2010 | FIRE - FINAL | LTHOMAS | Approved | |
05/10/2010 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR FINAL |
05/10/2010 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
05/13/2010 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* 1) CLEAR DRAIN PAN TERMINATIONS 2) CORRECT LEAK AT PRV |
05/14/2010 | FIRE - HYDRANTS | LTHOMAS | Approved | |
05/14/2010 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
05/14/2010 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
06/09/2010 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
06/09/2010 | ELECTRIC - FINAL | RMORENO | Approved | IVRS - Inspection :* |
06/09/2010 | OUTDOOR LIGHTING FINAL | RMORENO | Approved | IVRS - Inspection :* |
06/09/2010 | ELECTRIC - OUTDOOR LIGHTING | RMORENO | Approved | IVRS - Inspection :* |
06/09/2010 | ELECTRIC - PROGRESS | RMORENO | Approved | IVRS - Inspection :* |
06/09/2010 | ELECTRIC - CONSTRUCTION POWER | RMORENO | Approved | IVRS - Inspection :* |
06/22/2010 | LANDSCAPE - FINAL | MRUSSO | Approved | |
06/22/2010 | ENGINEERING - FINAL | MRUSSO | Approved | |
07/22/2010 | RIGHT OF WAY - FINAL | PWhiddon | Approved |