Permit: T08CM01711
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
3526 E FORT LOWELL RD 02
Address NEW:
3526 E FORT LOWELL RD 02
Apply Date:
05/27/2008
Applicant:
N/A
Description:
NEW METAL BUILDING
Architects:
- SBBL ARCHITECTURE + PLANNING *C
Contractors:
- COBRE BUILDING SYSTEMS INC ,
Permit Reviews
Permit Number - T08CM01711
Permit Status: C of o
Permit Description: NEW METAL BUILDING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/27/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 05/27/2008 | COMPLETED |
| 05/27/2008 | 3RD PARTY REVIEW-COMMERCIAL | 07/10/2008 | COMPLETED |
| 07/10/2008 | POST 3RD PARTY REVIEW | 07/10/2008 | COMPLETED |
| 09/11/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 09/11/2008 | COMPLETED |
| 10/13/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 10/14/2008 | COMPLETED |
| 12/01/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 12/04/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM01711
Permit Status: C of o
Permit Description: NEW METAL BUILDING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/27/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM01711
Permit Description: NEW METAL BUILDING
Total Completed Inspections - 34
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2008 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* PRE-SLAB OK |
| 10/14/2008 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection : The grounding electrode conductor is not installed per code.| 220* INSTALL AS PER 250.50 & 64 --- WHEN PRESENT APPLIES |
| 10/14/2008 | BUILDING PRE-SLAB | JBURGE | Approved | IVRS - Inspection :* OK TO POUR SLAB - SOUTH PORTION TO BE POURED FIRST; DETAIL #1 & #2 OF FOUNDATION PLAN NOTES |
| 11/17/2008 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 11/21/2008 | PLUMBING - SEWER HCS CONNECT | BBENEDON | Approved | IVRS - Inspection :* |
| 11/24/2008 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* COPPER RPPBP CONNECTED OK OK TO COVER YARD WATER PIPING |
| 12/13/2008 | ELECTRIC - PROGRESS | RHOLLAND | Approved | IVRS - Inspection :* 1) RECEIVED CHECK #52419 FOR $150.00 |
| 12/15/2008 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR #1 PER R. HOLLANDER |
| 12/16/2008 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* OK PVC CONDUITS TEP TO BUILDING 4" AND 2" BUILDING TO BUILDING |
| 12/31/2008 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* 1) SITE WALL |
| 01/21/2009 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* RESTROOMS - HARD CEILINGS -- NO T-GRID SYSTEM PRESENT |
| 01/22/2009 | FRAMING | JBURGE | Approved | IVRS - Inspection :* RESTROOMS AND BREAKROOM COMPLETE OK TO SHEETROCK |
| 01/26/2009 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* |
| 01/27/2009 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO TAPE THROUGHOUT |
| 02/02/2009 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 02/09/2009 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection :* CLOSET FLANGES OK HOSE BIBBS OK OK TO COVER ALL AREAS |
| 02/09/2009 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 02/17/2009 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 02/17/2009 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1. CONTRACTOR TO INSULATE HOT PIPING AT WH 2. CONTRACTOR TO INSTALL VACUUM RELIEF VALVE AT WH 3. PLUMBING FINAL OK |
| 02/17/2009 | NPPO - FINAL | ACONNOR | Approved | |
| 02/17/2009 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 02/17/2009 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 02/17/2009 | FIRE - FINAL | LTHOMAS | Approved | |
| 02/18/2009 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* GFI NOT PROPERLY INSTALLED SEE BUILDING INSPECTOR FOR C OF O |
| 02/18/2009 | MECHANICAL - PROGRESS | MRAMBER | Approved | IVRS - Inspection :* |
| 02/18/2009 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 02/18/2009 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
| 02/18/2009 | BUILDING - PROGRESS | JBURGE | Approved | IVRS - Inspection :* |
| 02/19/2009 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | |
| 02/19/2009 | BUILDING - FINAL | JBURGE | Approved | IVRS - Inspection :* |
| 02/19/2009 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
| 02/19/2009 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
| 02/19/2009 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
| 02/20/2009 | ENGINEERING - FINAL | MRUSSO | Approved |