Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Apply Date:
03/19/2008
Applicant:
RICHARD G GREEN
Description:
PARKING AND NEW BASEBALL FIELD
Architects:
  • GREEN, RICHARD G
Contractors:
  • ANDERSON CONSTRUCTION CORP , M

Permit Reviews

Permit Number - T08CM00917
Permit Status: Final
Permit Description: PARKING AND NEW BASEBALL FIELD
Start Date Submittal Complete Date Status  
03/19/2008 PLANS OK TO SUBMIT - 3RD PARTY 03/20/2008 COMPLETED Review Details
03/19/2008 PLANS OK TO SUBMIT - SITE 03/19/2008 COMPLETED Review Details
03/20/2008 3RD PARTY REVIEW-COMMERCIAL 05/02/2008 COMPLETED Review Details
03/20/2008 SITE 05/02/2008 COMPLETED Review Details
05/02/2008 POST 3RD PARTY REVIEW 05/22/2008 COMPLETED Review Details
05/02/2008 SITE 05/22/2008 COMPLETED Review Details
06/05/2008 3RD PARTY REVIEW-REVISION/OTHER 06/10/2008 COMPLETED Review Details
11/17/2008 POST 3RD PARTY REVIEW 11/18/2008 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM00917
Permit Status: Final
Permit Description: PARKING AND NEW BASEBALL FIELD
Total Outstanding Activity Conditions - 1
Date Name
03/19/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T08CM00917
Permit Description: PARKING AND NEW BASEBALL FIELD
Total Completed Inspections - 20
Date Description Inspector Results Comments
07/09/2008 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*
07/10/2008 SEPTIC - SYSTEM BBENEDON Approved IVRS - Inspection :*
1. THE SEPTIC SYSTEM SHALL BE INSPECTED BY PIMA COUNTY
2. THE SITE SEWER HOWEVER REQUIRES CITY INSPECTION
3. PLEASE HAVE SEWER PRE-CONSTRUCTION MEETING AND SITE SEWER ADDED TO YOUR PERMIT
4. CALL FOR PRE-CONST. INSP. AND COORDINATE TO HAVE CONTRACTOR, ENGINEER AND CITY INSPECTION AT MEETING
5. EXPOSE PIPING COVERED W/OUT INSPECTION
07/15/2008 SEWER - PRE CONSTRUCTION MTG RRICH Approved IVRS - Inspection :*
MEETING WITH HARRY & ADAM OF GREEN RIDGE CONST.
JACK & RON - ANDERSON
BON - RS ENGINEERING
TRINI - WILDAN

SEWER TO BE EXPOSED, AT MANHOLE AND CHANGE OF DIRECTION WITH CLEANOUT EXPOSED, AIR TESTED OF SEWER, VACUUM TEST OF NEW MANHOLE WITH CORRECT COUPLING BETWEEN MANHOLE & SEPTIC TANK AND TEST ON THIS SECTION AT LATER DATE. CONTRACTOR TO PROVIDE ACTUAL SEWER FLOW SURVEY FROM LICENSED SURVEYING COMPANY
10/01/2008 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection :*
10/08/2008 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
1" PVC SCH 40 FROM POINT OF CONNECTION TO RPB FOR LANDSCAPING, WITH 1/2" DRINKING FOUNTAIN SUPPLY TIED INTO 1/2" COPPER AT EQUESTRIAN CENTER
10/09/2008 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
1) DRYWALL INSTALLED AT THIS SITE
2) APPROVED TIED INTO BLDG
10/21/2008 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
OK GROUND RODS - SERVICE & POLES
OK 1 1/2" PVC FOR IRRIGATION CONTROLS
10/21/2008 FRAMING AQUIROZ Approved IVRS - Inspection :*
10/21/2008 ROOF NAILING AQUIROZ Approved IVRS - Inspection :*
12/23/2008 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
RECEIVED BACTERIA REPORT, PCDEQ AUTHORIZATION TO DISCHARGE ON SITE.
12/23/2008 SITE - SEWER RRICH Approved IVRS - Inspection :*
04/06/2009 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR 1M & 2M PER D. SANTACRUZ
04/23/2009 ELECTRIC - CABLE DROP DSANTACR Approved
04/23/2009 ELECTRIC - CONSTRUCTION POWER DSANTACR Approved IVRS - Inspection :*
04/23/2009 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved IVRS - Inspection :*
04/23/2009 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
04/23/2009 OUTDOOR LIGHTING FINAL DSANTACR Approved IVRS - Inspection :*
04/23/2009 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
08/06/2009 BUILDING - FINAL LHANLY Approved IVRS - Inspection :*
08/07/2009 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
001__G1.1.TIF CONSTRPLANS VIEW
002__C3.0.TIF CONSTRPLANS VIEW
003__C3.1.TIF CONSTRPLANS VIEW
004__C3.2.TIF CONSTRPLANS VIEW
005__C4.0.TIF CONSTRPLANS VIEW
006__C4.1.TIF CONSTRPLANS VIEW
007__C4.2.TIF CONSTRPLANS VIEW
008__L1.0.TIF CONSTRPLANS VIEW
009__L1.1.TIF CONSTRPLANS VIEW
010__L1.2.TIF CONSTRPLANS VIEW
011__L1.3.TIF CONSTRPLANS VIEW
012__L1.4.TIF CONSTRPLANS VIEW
013__L1.5.TIF CONSTRPLANS VIEW
014__L1.6.TIF CONSTRPLANS VIEW
015__L1.7.TIF CONSTRPLANS VIEW
016__L1.8.TIF CONSTRPLANS VIEW
017__L1.9.TIF CONSTRPLANS VIEW
018__L2.1.TIF CONSTRPLANS VIEW
019__L2.2.TIF CONSTRPLANS VIEW
020__L2.3.TIF CONSTRPLANS VIEW
021__L3.1.TIF CONSTRPLANS VIEW
022__L3.2.TIF CONSTRPLANS VIEW
023__L3.3.TIF CONSTRPLANS VIEW
024__L3.4.TIF CONSTRPLANS VIEW
025__L3.5.TIF CONSTRPLANS VIEW
026__L4.1.TIF CONSTRPLANS VIEW
027__L4.2.TIF CONSTRPLANS VIEW
028__L4.3.TIF CONSTRPLANS VIEW
029__L4.4.TIF CONSTRPLANS VIEW
030__L4.5.TIF CONSTRPLANS VIEW
031__L4.6.TIF CONSTRPLANS VIEW
032__L4.7.TIF CONSTRPLANS VIEW
033__L4.8.TIF CONSTRPLANS VIEW
034__E1.TIF CONSTRPLANS VIEW
035__E2.TIF CONSTRPLANS VIEW
036__E3.TIF CONSTRPLANS VIEW
037__E4.TIF CONSTRPLANS VIEW
038__E5.TIF CONSTRPLANS VIEW
039__E6.TIF CONSTRPLANS VIEW
040__E7.TIF CONSTRPLANS VIEW
041__E8.TIF CONSTRPLANS VIEW
042__E9.TIF CONSTRPLANS VIEW
043__E10.TIF CONSTRPLANS VIEW
044__E11.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
STRUCCALCS_02.TIF DOCUMENTS VIEW
STRUCCALCSRECREATIONSYS.TIF DOCUMENTS VIEW
STRUCDESIGNCOMPUTATIONS.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW