Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T08CM00424
Permit Details
Apply Date:
02/07/2008
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI:WAITING AREA FOR CAR DEALERSHIP
Contractors:
- CANYON BUILDING AND DESIGN L L C
Permit Reviews
Permit Number - T08CM00424
Permit Status: C of o
Permit Description: TI:WAITING AREA FOR CAR DEALERSHIP
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/07/2008 | PLANS OK TO SUBMIT - 3RD PARTY | 02/07/2008 | COMPLETED |
02/07/2008 | 3RD PARTY REVIEW-COMMERCIAL TI | 02/22/2008 | COMPLETED |
02/12/2008 | SITE | 03/07/2008 | COMPLETED |
02/22/2008 | POST 3RD PARTY REVIEW | 10/14/2008 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM00424
Permit Status: C of o
Permit Description: TI:WAITING AREA FOR CAR DEALERSHIP
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/07/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T08CM00424
Permit Description: TI:WAITING AREA FOR CAR DEALERSHIP
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/06/2008 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* |
03/12/2008 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* |
03/19/2008 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
03/21/2008 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* |
03/31/2008 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
03/31/2008 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
04/08/2008 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
04/08/2008 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
04/16/2008 | MECHANICAL - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
04/16/2008 | ELECTRIC - PROGRESS | RJIROUDE | Approved | IVRS - Inspection :* |
04/16/2008 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* |
04/16/2008 | ELECTRIC - INTERMEDIATE | RJIROUDE | Approved | IVRS - Inspection :* |
05/12/2008 | ENGINEERING - FINAL | DROBERTS | Approved | |
05/12/2008 | NPPO - FINAL | ACONNOR | Approved | N/A |
05/12/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | N/A |
05/12/2008 | NPPO - FINAL | ACONNOR | Approved | |
05/12/2008 | BUILDING - PROGRESS | GDABBS | Approved | IVRS - Inspection :* |
05/12/2008 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
05/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | GDABBS | Approved | IVRS - Inspection :* |
05/12/2008 | SIGN - FINAL | JYBARRA | Approved | |
05/13/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* TESTED DUCT SMOKE DETECTOR OK FOR FINAL |
05/13/2008 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
05/13/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
05/13/2008 | FIRE - FINAL | LTHOMAS | Approved | |
05/15/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
05/15/2008 | ELECTRIC - CABLE DROP | RJIROUDE | Approved | IVRS - Inspection :* |
05/15/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |