Permit Details

Status:
Expired
Type:
MULTI FAMILY ALTERATION
Apply Date:
01/02/2008
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI:APARTMENTS
Architects:
  • MCQUILLEN, THOMAS
Contractors:
  • SCHEMEL TARRILLION INC

Permit Reviews

Permit Number - T08CM00011
Permit Status: Expired
Permit Description: TI:APARTMENTS
Start Date Submittal Complete Date Status  
01/02/2008 PLANS OK TO SUBMIT - COMM 01/09/2008 COMPLETED Review Details
01/09/2008 3RD PARTY REVIEW-COMMERCIAL 02/11/2008 COMPLETED Review Details
02/11/2008 POST 3RD PARTY REVIEW 03/31/2008 COMPLETED Review Details
07/01/2009 REVISION - - 1ST 07/02/2009 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T08CM00011
Permit Status: Expired
Permit Description: TI:APARTMENTS
Total Outstanding Activity Conditions - 1
Date Name
01/02/2008 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T08CM00011
Permite Description: TI:APARTMENTS
Total Outstanding Inspections - 14
Last Inspection Date Description Inspector Results Comments
FRAMING N/A Not Inspected
SHEET ROCK NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
01/08/2009 ELECTRIC - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE T08CM00008
01/08/2009 ELECTRIC - ABOVE CEILING N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE T08CM00008
01/08/2009 ELECTRIC - TEMPORARY SERVICE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE T08CM00008
01/08/2009 ELECTRIC - TEMP POWER FOR TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE T08CM00008
01/08/2009 ELECTRIC - SERVICE UPGRADE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE T08CM00008
01/08/2009 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE T08CM00008
01/08/2009 PLUMBING - INTERMEDIATE N/A Not ready for Inspection IVRS - Inspection :*
1. NO APPROVED PLAN ON SITE
2. NO SPEC. BOOK PLAN DOES NOT SHOW MATERIAL TYPES, INSTALLATION STD., ETC.
3. PLAN DOES NOT MEET CODE - I.E. AT LAUNDRY AREA WASTE AND VENT UNDERSIZED AS STAND PIPES IN BATTERIES OF 3 OR MORE EQUAL 6 D.F.M
4. ALL WORK COVERED W/O INSPECTION
5. EXTENSIVE PLUMBING HAS BEEN INSTALLED
6. ALL HOT WATER AND RETURN PIPING TO BE INSULATED
PLAN DOESN'T INDICATE WHAT TYPE OF INSULATION
7. EXPOSE ALL WORK
8. HAVE WORK READY AND TESTED AT TIME OF INSPECTION
01/08/2009 PLUMBING - PROGRESS N/A Not ready for Inspection IVRS - Inspection :*
01/08/2009 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
01/08/2009 FIRE SPKLR - FINAL N/A Denied Need a up to date 5 year alarm check valve inspection done, last one on file 02/27/2003.
01/08/2009 FIRE - ALARM FINAL N/A Denied Need a up to date fire alarm inspection done, last one on file 02/26/2002.