Permit: T08CM00011
Permit Details
Apply Date:
01/02/2008
Applicant:
METRO PERMIT EXPRESS, INC *C
Description:
TI:APARTMENTS
Architects:
- MCQUILLEN, THOMAS
Contractors:
- SCHEMEL TARRILLION INC
Permit Reviews
Permit Number - T08CM00011
Permit Status: Expired
Permit Description: TI:APARTMENTS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/02/2008 | PLANS OK TO SUBMIT - COMM | 01/09/2008 | COMPLETED |
01/09/2008 | 3RD PARTY REVIEW-COMMERCIAL | 02/11/2008 | COMPLETED |
02/11/2008 | POST 3RD PARTY REVIEW | 03/31/2008 | COMPLETED |
07/01/2009 | REVISION - - 1ST | 07/02/2009 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T08CM00011
Permit Status: Expired
Permit Description: TI:APARTMENTS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
01/02/2008 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T08CM00011
Permite Description: TI:APARTMENTS
Total Outstanding Inspections - 14
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
FRAMING | N/A | Not Inspected | ||
SHEET ROCK NAILING | N/A | Not Inspected | ||
BUILDING - FINAL | N/A | Not Inspected | ||
01/08/2009 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE T08CM00008 |
01/08/2009 | ELECTRIC - ABOVE CEILING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE T08CM00008 |
01/08/2009 | ELECTRIC - TEMPORARY SERVICE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE T08CM00008 |
01/08/2009 | ELECTRIC - TEMP POWER FOR TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE T08CM00008 |
01/08/2009 | ELECTRIC - SERVICE UPGRADE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE T08CM00008 |
01/08/2009 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE T08CM00008 |
01/08/2009 | PLUMBING - INTERMEDIATE | N/A | Not ready for Inspection | IVRS - Inspection :* 1. NO APPROVED PLAN ON SITE 2. NO SPEC. BOOK PLAN DOES NOT SHOW MATERIAL TYPES, INSTALLATION STD., ETC. 3. PLAN DOES NOT MEET CODE - I.E. AT LAUNDRY AREA WASTE AND VENT UNDERSIZED AS STAND PIPES IN BATTERIES OF 3 OR MORE EQUAL 6 D.F.M 4. ALL WORK COVERED W/O INSPECTION 5. EXTENSIVE PLUMBING HAS BEEN INSTALLED 6. ALL HOT WATER AND RETURN PIPING TO BE INSULATED PLAN DOESN'T INDICATE WHAT TYPE OF INSULATION 7. EXPOSE ALL WORK 8. HAVE WORK READY AND TESTED AT TIME OF INSPECTION |
01/08/2009 | PLUMBING - PROGRESS | N/A | Not ready for Inspection | IVRS - Inspection :* |
01/08/2009 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
01/08/2009 | FIRE SPKLR - FINAL | N/A | Denied | Need a up to date 5 year alarm check valve inspection done, last one on file 02/27/2003. |
01/08/2009 | FIRE - ALARM FINAL | N/A | Denied | Need a up to date fire alarm inspection done, last one on file 02/26/2002. |