Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T08CM00011
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/08/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. NO APPROVED PLAN ON SITE 2. NO SPEC. BOOK PLAN DOES NOT SHOW MATERIAL TYPES, INSTALLATION STD., ETC. 3. PLAN DOES NOT MEET CODE - I.E. AT LAUNDRY AREA WASTE AND VENT UNDERSIZED AS STAND PIPES IN BATTERIES OF 3 OR MORE EQUAL 6 D.F.M 4. ALL WORK COVERED W/O INSPECTION 5. EXTENSIVE PLUMBING HAS BEEN INSTALLED 6. ALL HOT WATER AND RETURN PIPING TO BE INSULATED PLAN DOESN'T INDICATE WHAT TYPE OF INSULATION 7. EXPOSE ALL WORK 8. HAVE WORK READY AND TESTED AT TIME OF INSPECTION |