Permit: T07PL01468
Permit Details
Apply Date:
08/16/2007
Applicant:
PAUL OLSEN
Description:
REPLACE:GAS LINE
Permit Reviews
Permit Number - T07PL01468
Permit Status: Final
Permit Description: REPLACE:GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/16/2007 | PLUMBING | 08/16/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07PL01468
Permit Status: Final
Permit Description: REPLACE:GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/16/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07PL01468
Permit Description: REPLACE:GAS LINE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2007 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE MINIMUM 10 PSI TEST USING TEST GAUGE IN 1/10 POUND INCREMENTS WITH NO LOSS OF PRESSURE FOR 15 MINUTES IN PLACE AT REINSPECTION 2. PROVIDE ACCESS TO ROOF FOR INSPECTION 3. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN 4. PROVIDE CORRECT SUPPORTS & SECURE ALL PIPING PROPERLY 5. REMOVE TAPE FROM WATER HEATER VENT PIPING, NOTE: THIS PIPING SHALL MEET REQUIREMENTS FOR 2006 UPC 6. SHALL PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO FURNACE AND WATER HEATER 7. SHALL PROVIDE RIDGID NIPPLE THRU APPLIANCE HOUSING AT FURNACE LIST MAY NOT BE COMPLETE |
| 12/12/2007 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 05/12/2008 | PERMIT FINALED | BFLORES | Approved |