Permit: T07PL01468

Parcel: 135102090


Addresses:

7345 E 31ST ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/09/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
04/30/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE #4 WIRE FOR BONDING GAS SYSTEM
2. PROVIDE APPROVED T&P DRAIN MATERIAL (CPVC, COPPER, GALVANIZED METAL PIPE)
02/28/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE ROOF FLASHINGS FOR PIPE PENETRATIONS
THRU ROOF
2. SEE NOTES #3, #5, #6 FROM 12/12/07
3. ORIENT PIPING IN WATER HEATER AREA TO PROVIDE PULL SPACE FOR WATER HEATER
4. EXTEND VENT FROM FURNACE TO 3' ABOVE TOP OF AIR INTAKE WITH DOUBLE WALL VENT PIPING
5. PROVIDE BONDING OF BUILDING GAS PIPING
12/12/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE MINIMUM 10 PSI TEST USING TEST GAUGE IN 1/10 POUND INCREMENTS WITH NO LOSS OF PRESSURE FOR 15 MINUTES IN PLACE AT REINSPECTION
2. PROVIDE ACCESS TO ROOF FOR INSPECTION
3. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN
4. PROVIDE CORRECT SUPPORTS & SECURE ALL PIPING PROPERLY
5. REMOVE TAPE FROM WATER HEATER VENT PIPING,
NOTE: THIS PIPING SHALL MEET REQUIREMENTS FOR 2006 UPC
6. SHALL PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO FURNACE AND WATER HEATER
7. SHALL PROVIDE RIDGID NIPPLE THRU APPLIANCE HOUSING AT FURNACE

LIST MAY NOT BE COMPLETE