Permit: T07PL01410
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
2118 W SADDLE HILLS DR
Address NEW:
2118 W SADDLE HILLS DR
Apply Date:
08/08/2007
Applicant:
MR ROOTER PLUMBING *C
Description:
REPL SEWER LINE
Contractors:
- MR ROOTER PLUMBING *C
Permit Reviews
Permit Number - T07PL01410
Permit Status: Final
Permit Description: REPL SEWER LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/08/2007 | PLUMBING | 08/08/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07PL01410
Permit Status: Final
Permit Description: REPL SEWER LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/08/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07PL01410
Permit Description: REPL SEWER LINE
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) CONTRACTOR HAS CUT IN/REPLACED TWO WAY CLEANOUT AT THE PROPERTY LINE AND AT THE HOUSE 2) OK TO COVER 3) PLUMBER PLEASE NOTE FOR FUTURE REFERENCE: CLEANOUTS ARE TO OPEN IN THE DIRECTION OF THE FLOW. THE ONLY PLACE YOU CAN HAVE A CLEANOUT INSTALLED AGAINST FLOW IS AT THE TWO WAY CLEANOUT, WHERE THE BLDG DRAIN CONNECTS TO THE BLDG SEWER |
| 08/13/2007 | PERMIT FINALED | JWEATHER | Approved |