Permit: T07PL01279
Permit Details
Apply Date:
07/20/2007
Applicant:
MICAELA PIZANO
Description:
REPL GAS LINE
Permit Reviews
Permit Number - T07PL01279
Permit Status: Expired
Permit Description: REPL GAS LINE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/20/2007 | PLUMBING | 07/20/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07PL01279
Permit Status: Expired
Permit Description: REPL GAS LINE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/20/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T07PL01279
Permite Description: REPL GAS LINE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2007 | PLUMBING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE BONDING OF BUILDING GAS PIPING #4 SOLID COPPER WIRE (2) CLAMPS 2. VENT FROM FURNACE TO BE EXTENDED UP WITH FULL SIZE DOUBLE WALL VENT PIPING TO 3' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF INTAKE 3. REMOVE DRYWALL FROM LOWER COMBUSTION AIR INTAKE BY DOOR OF WATER HEATER ROOM 4. SUPPORT GAS PIPING TO WATER HEATER |
Completed Inspections
Permit Status: Expired
Permit Number: T07PL01279
Permit Description: REPL GAS LINE
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2007 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* |