Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
10681 E KEYSTONE RD
Apply Date:
05/25/2007
Applicant:
LUCAREVSKIY OLENA & LUCAREVSKIY IGOR
Description:
REPAIR:GAS LINE
Contractors:
  • CODE BLUE PLUMBING AND DRAINS L L C * C

Permit Reviews

Permit Number - T07PL00919
Permit Status: Expired
Permit Description: REPAIR:GAS LINE
Start Date Submittal Complete Date Status  
05/25/2007 PLUMBING 05/25/2007 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T07PL00919
Permit Status: Expired
Permit Description: REPAIR:GAS LINE
Total Outstanding Activity Conditions - 1
Date Name
05/25/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07PL00919
Permite Description: REPAIR:GAS LINE
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
05/29/2007 PLUMBING - GAS PRESSURE TEST N/A Not ready for Inspection IVRS - Inspection :*
05/29/2007 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SHALL HAVE TEST ON ENTIRE GAS SYSTEM AT TIME OF INSPECTION TEST SHALL HOLD WITH NO LOSS OF PRESSURE.
2. SHALL PROVIDE RIDGID NIPPLE THRU APPLIANCE HOUSING AT FURNACE.
3. REMOVE TAPE AT SINGLE TO DOUBLE WALL VENT CONNECTION AT FURNACE & PROVIDE 3-GALV SCREWS AT EACH JOINT.
4. MAKE UP VENT CORRECTLY AT WATER HEATER AND PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING.
5. PROVIDE SEDIMENT TRAPS AT GAS ENTRY TO FURNACE AND WATER HEATER.
6. PROVIDE BONDING OF BUILDING GAS PIPING.
7. PROVIDE WORKABLE AGA OR CSA GAS VALVES AT APPLIANCES.

Documents

File Name Document Type  
None DOCUMENTS VIEW