Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T07PL00663
Permit Details
Apply Date:
04/12/2007
Applicant:
CUMMINGS PLUMBING INC , *C
Description:
GAS LINE:REPLACE
Contractors:
- CUMMINGS PLUMBING INC , *C
Permit Reviews
Permit Number - T07PL00663
Permit Status: Final
Permit Description: GAS LINE:REPLACE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/12/2007 | PLUMBING | 04/12/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07PL00663
Permit Status: Final
Permit Description: GAS LINE:REPLACE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/12/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T07PL00663
Permit Description: GAS LINE:REPLACE
Total Completed Inspections - 4
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/13/2007 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |
04/19/2007 | PLUMBING - FINAL | RLEDONNE | Approved | IVRS - Inspection :* |
04/19/2007 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. SECURE EACH JOINT ON VENT CONNECTOR WITH 3 GALV SHEETMETAL SCREWS. 2. SECURE CONNECTION BETWEEN VENT CONNECTOR AND B VENT W/3 GALV SHEET METAL SCREWS. USE NO TAPE. 3. PLUG DRAIN PAN HOLE (GLUE) 4. PROVIDE PETITION OF APPEAL FOR WATER HEATER T&P TERMINATION OR PIPE TO EXTERIOR. 5. READ NOTES FROM PREVIOUS INSP. |
04/20/2007 | PERMIT FINALED | BFLORES | Approved |