Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
Permit Number - T07PL00663
Inspection Description - PLUMBING - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SECURE EACH JOINT ON VENT CONNECTOR WITH 3 GALV SHEETMETAL SCREWS. 2. SECURE CONNECTION BETWEEN VENT CONNECTOR AND B VENT W/3 GALV SHEET METAL SCREWS. USE NO TAPE. 3. PLUG DRAIN PAN HOLE (GLUE) 4. PROVIDE PETITION OF APPEAL FOR WATER HEATER T&P TERMINATION OR PIPE TO EXTERIOR. 5. READ NOTES FROM PREVIOUS INSP. |
|
04/19/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
04/13/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PRESSURE TEST OK 2. NEW HOSE BIB AT RELIEF VALVE REQUIRES A VACUUM BREAKER. 3. RELIEF VALVE TERMINATION IS 6" ABV GRADE 4. PIPE TPR DRAIN TO EXTERIOR OR PROVIDE PETITION OF APPEAL FROM BUILDING OFFICIAL. 5. SECURE VENT CONNECTORS W/SCREWS, PROPERLY MAKE UP CONNECTIONS. 6. NEW GAS YARD PIPING OK TO COVER 7. PIPING IN HOUSE IS EXISTING 8. UTILITY CLEARANCE GIVEN 9. RECALL FINAL INSPECTION AFTER CORRECTING ITEMS LISTED. |