Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Permit Number - T07PL00663

Inspection Description - PLUMBING - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
04/19/2007 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SECURE EACH JOINT ON VENT CONNECTOR WITH 3 GALV SHEETMETAL SCREWS.
2. SECURE CONNECTION BETWEEN VENT CONNECTOR AND B VENT W/3 GALV SHEET METAL SCREWS. USE NO TAPE.
3. PLUG DRAIN PAN HOLE (GLUE)
4. PROVIDE PETITION OF APPEAL FOR WATER HEATER T&P TERMINATION OR PIPE TO EXTERIOR.
5. READ NOTES FROM PREVIOUS INSP.
04/19/2007 PLUMBING - FINAL Approved IVRS - Inspection :*
04/13/2007 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PRESSURE TEST OK
2. NEW HOSE BIB AT RELIEF VALVE REQUIRES A VACUUM BREAKER.
3. RELIEF VALVE TERMINATION IS 6" ABV GRADE
4. PIPE TPR DRAIN TO EXTERIOR OR PROVIDE PETITION OF APPEAL FROM BUILDING OFFICIAL.
5. SECURE VENT CONNECTORS W/SCREWS, PROPERLY MAKE UP CONNECTIONS.
6. NEW GAS YARD PIPING OK TO COVER
7. PIPING IN HOUSE IS EXISTING
8. UTILITY CLEARANCE GIVEN
9. RECALL FINAL INSPECTION AFTER CORRECTING ITEMS LISTED.