Description:
REPLACE: WATER HEATER (APA)
Contractors:
  • ARIZONA PLUMBING SERVICES *C

Outstanding Activity Conditions

Permit Number - T07PL00283
Permit Status: Expired
Permit Description: REPLACE: WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
Date Name
02/06/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T07PL00283
Permite Description: REPLACE: WATER HEATER (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/07/2007 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SHALL PROVIDE EACH PAN UNDER WATER HEATER FOR ELEVATED FLOOR WITH DRAIN.
2. VENT TO BE DOUBLE WALL LEAVING ENCLOSURE
MINIMUM 1' ABOVE ROOF WITH APPROVED VENT CAP
JOINTS OF VENT PIPING SHALL HAVE 3-GALV SCREWS AT EACH JOINT.